Hypochlorous Weak Acid Water Generator With PH 5.0 - 6.5 For Swimming Pool
Brief Introduction
Hypochlorous acid generator is an eco-friendly electrolyzed water generator to produce electrolyzed solution for sterilization through the electrolysis of water and electrolyte. Its sanitizing effects killing bacteria and microorganisms have been proven in a wide range of medical applications. The hypochlorous acid generator produces an eco-friendly and revolutionary sterilizer that is much safer than the traditional chemical agents and can be conveniently employed in a wide variety of applications.
Principle of electrolysis
The strong acid electrolytic ion water equipment electrolyzes a certain proportion of diluted brine (NaCl) in a special electrolytic module. In the advanced polymer membrane, the anode side is strongly acidic oxidation potential water, and the cathode side is alkali sexual reduction potential water.
Unlike other electrolytic cells, here a diaphragm separates the Anolyte and Catholyte that are generated respectively at the anode and cathode chambers of the cell. This prevents the two streams from mixing and inter-reacting to form a simple sodium hypochlorite solution as is the case with other electrolytic cells commercially available now.
Feature of the hypochlorous acid generator
1. Water quality pretreatment system
2. Sodium chloride electrolyte water tank monitoring system, reminding to replace electrolyte
3. Modular design of the electrolyzer, the electrolysis module can be increased by different water demand
4. PH monitoring system, real-time monitoring of PH value of electrolyzed water
5. PLC, touch screen design, fully automated electrolysis mode. Some modules can be selected to work, which is convenient and efficient.
Difference between Slightly Acidic Electrolyzed Water and sodium hypochlorite
Item | Slightly Acidic Electrolyzed Water | NaClO Sodium Hypochlorite |
Odor | No odor or slight chlorine odor | Strong chlorine odor |
Eco-friendly Water Discharge | No neutralizing agent required | Neutralization tank required. Trihalomethane & chloroform generated. |
Working Environment | Drastically improved | Strong odor, poisonous gas, and rough hands caused, requiring improvement |
Post-treatment | Also used as rinsing water | A large amount of rinsing water required for odor & medical agent removal |
Saline Residue | None | The residue causes the metal to corrode. |
Specifications:
Model | Water Flow Rate | Chlorine Capacity | Water treatment capacity | PH | concentration |
GBW-500-HCLO | 500 L / h | 50 g / h | 50 ton / h | 5.0 – 6.5 | 50~100 ppm |
GBW-600-HCLO | 600 L / h | 60 g / h | 60 ton / h | 5.0 – 6.5 | 50~100 ppm |
GBW-700-HCLO | 700 L / h | 70 g / h | 70 ton / h | 5.0 – 6.5 | 50~100 ppm |