Magnetic Fenton Package System for Printing Waste water
Geemblue Magnetized Fenton Process
Use fixed-point removal method to oxidize COD , H202 consumption is extremely low, 40% cheaper than traditional Fenton.
Firstly magnetize the wastewater, change the arrangement position between pollutant molecules and water molecules, so that hydroxyl radicals can easily contact COD ,
Geemblue Magnetic Fenton scene
Specifications:
Process | 27.5% H2O2 (mg/L) | FeSO4.7H2O (mg/L) | 98% H2SO4 mg/L | 30% NaOH mg/L | Chemical cost USD / ton of water |
Geemblue Magnetic Fenton | 190 | 290 | 210 | 510 | 0.1948 |
fluidized bed Fenton | 420 | 350 | 290 | 784 | 0.3151 |
Traditional Fenton | 510 | 420 | 360 | 860 | 0.3662 |