Magnetic Fenton Package System for Printing Waste water
Geemblue Magnetized Fenton Process
Use fixed-point removal method to oxidize COD , H202 consumption is extremely low, 40% cheaper than traditional Fenton.
Firstly magnetize the wastewater, change the arrangement position between pollutant molecules and water molecules, so that hydroxyl radicals can easily contact COD ,
Chemical process principle of Fenton
Under acidic conditions, H2O2 reacts with Fe2+ to produce hydroxyl radicals, which have strong oxidizing ability to quick oxidize and decompose the organic matter which is difficult to degrade.
Reaction equation: H202+Fe2+ →Fe3++OH-+·OH
Fe2+ is catalyst, H202 is oxidant, ·OH is hydroxyl radical, and the amount of hydroxyl radical generation is determined by Fe2+ and H202. Fenton’s key point is the oxidizing ability of hydroxyl radicals, which have two path after they are produced:
1. It does not contact pollutants and decomposes naturally, causing waste;
2. Contact to pollutants and oxidation.
Specifications:
Item | CODcr (mg/L) | Total Nitrogen | SS (mg/L) | Total Phosphorus | PH |
Inlet water | ≤ 100 | ≤ 15 | ≤ 20 | ≤ 2 | 6~9 |
Outlet water | ≤ 50 | ≤ 15 | ≤ 20 | ≤ 0.5 | 6~9 |