Specifications
Brand Name :
Geemblue
Model Number :
XFDM02B
Certification :
ISO9001 CE
Place of Origin :
CHINA
MOQ :
1 set
Price :
NEGOTIATION
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
10 SET/MONTH
Delivery Time :
30-60 work days
Packaging Details :
wooden case
Model :
XFDM02B
Anode Material :
BDD
Cathode Material :
Titanium
Treatment Capacity :
By water quality
Number of Modules :
2-slot 4-module
Area of anode strip :
1.75m2
Description

Copper Recovery Equipment For Copper Nitrate Waste Solution

The principle of ion exchange adsorption is used to recover nickel from nickel-containing cleaning water discharged from the cleaning section or nickel-containing wastewater in the exchange tank of production lines such as nickel electroplating, electroless nickel and chemical nickel plating in PCB and electroplating enterpris- es. It can adjust the PH value to 4 ~ 6 and use nickel absorption chelating resin to selectively absorb nickel from rinse water and wastewater. The nickel-containing chelating resin is regenerated and recycled using dilute sulfuric acid for both forward rinsing and backwashing. The eluent of nickel-containing chelating resin, containing 20g/L-100g/L nickel sulfate (it can be directly returned to the nickel plating tanks or electrodeposited into nickel blocks in the electrolytic cell), is collected to recover nickel. This process offers significant economic benefits. The nickel content in the treated water is less than 0.1 mg/L, which meets the national discharge standard and successfully solves the problem that it is difficult to treat nickel-containing wastewater to meet the national discharge standard. Automatic control is adopted for equipment operation.

Nickel Recovery Equipment for Nickel-Containing Wastewater

Specifications:

Equipment model XFDM01 XFDM02 XFDM04
Equipment dimension (L×W×H, mm) 1094 x 794 x 1844 1392 x 1247 x 2048 1900 x 1500 x 1850
Operating weight of equipment(kg) 972 1947 650
Number of modules 1-slot 2-module 2-slot 4-module 4-slot 8-module
Anode material BDD
Cathode material Ti
Area of anode strip(㎡) 0.88 1.75 3.5
Treatment capacity(m³/h) By water quality
Single-batch processing time(h) By water quality
Design circulating flow(m³/h) 10 20 30
Head loss at design circulating flow(KPa) 20 20 40
Installed power(Kw) 10 20 40
Service power(Kw) ≤7 ≤12 ≤20
Current density(mA/c㎡) ≤70(≤301 A) ≤70(≤602 A) ≤70(≤1204 A)
Maximum heating power(Kw) 2.79 5.6 14
Input voltage AC 380 V/50 Hz AC 380 V/50 Hz AC 380 V/50 Hz
Power output DC 500 A/20 V DC 1000 A/20 V DC 2000 A/20 V
Operating ambient temperature 0 ℃ ~ 40 ℃
Relative humidity ≤90%
Installation method Indoor
Circulating water pump None
Pressure protection Optional
Temperature protection Optional
Inlet diameter DN50 flange DN50 flange DN80 flange
Outlet diameter DN50 flange DN50 flange DN80 flange
Send your message to this supplier
Send Now

Nickel Recovery Equipment for Nickel-Containing Wastewater

Ask Latest Price
Brand Name :
Geemblue
Model Number :
XFDM02B
Certification :
ISO9001 CE
Place of Origin :
CHINA
MOQ :
1 set
Price :
NEGOTIATION
Contact Supplier
Nickel Recovery Equipment for Nickel-Containing Wastewater

Guangzhou Geemblue Environmental Equipment Co., Ltd.

Verified Supplier
7 Years
guangdong, guangzhou
Since 1993
Business Type :
Manufacturer, Exporter
Total Annual :
5,000,000-10,000,000
Employee Number :
70~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement