• Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
• Built-in MPPT solar charge controller 100A
• MPPT efficiency max 98%
• Powerful charge rate up to 80Amp
• DC start &Automatic Self-Diagnostic Function
• USB monitoring function
• Supporting AGS, BTS port
• Compatible to generator
PV3500 TLV series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger
to offer uninterruptible power support. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery
charging current, AC/solar charger priority, and selectable input voltage based on different applications.
MODEL | PV35-8048 TLV | PV35-10048 TLV | |||
Default Battery System Voltage | 48VDC | 48VDC | |||
Inverter Output | Rated Power | 8kw | 10kw | ||
Surge Power | 2400VA | 30000VA | |||
Capable Of Starting Electric Motor | 4HP | 5HP | |||
Waveform | Pure sine wave /same as input(bypass mode) | ||||
Nominal Output Voltage RMS | 100V/110V/120V/200V/220V/240V | ||||
Output Frequency | 50Hz / 60Hz ±0.3 | ||||
Inverter Efficency(Peak) | >88% | ||||
Line Mode Efficiency | >95% | ||||
Power factor | 1 | ||||
Typical Transfer Time | 20ms(max) | ||||
AC Input | Voltage | 220V/230V/240V | |||
Selectable Voltage Range | 90-280 VAC (APL) | ||||
Frequency Range | 50Hz / 60Hz | ||||
Low Battery voltage cut off | 40-48VDC for 48VDC mode | ||||
Low Battery voltage recover | 42-50VDC for 48VDC mode | ||||
High Battery Voltage cut off | 60VDC for 48VDC mode | ||||
High Battery Voltage Recover | 57VDC for 48VDC mode | ||||
Idie Consumption-Search Mode | < 60W when power saver on | ||||
CHARGER | Output Voltage | Depends on battery type | |||
Charge AC Input Breaker Rating | 80A | 80A | |||
Overcharge Protection S.D. | 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) | ||||
Maximum Charge Current | 60A | 70A | |||
BTS | Continuous output power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | |||
BYPASS & PROTECTION |
Input Voltage Waveform | Sine wave (grid or generator) | |||
Nominal Input Frequency | 50Hz or 60Hz | ||||
Overload Protection (SMPS Load) | Circuit breaker | ||||
Output Short Circuit Protection | Circuit breaker | ||||
Bypass breaker rating | 63A | ||||
Max bypass current | 80Amp | ||||
SOLAR CHARGER | Maximum PV Array Open Circuit Voltage | 145VDC | |||
Maximum PV Charge Current | 100A | ||||
DC Voltage | 48V | ||||
Maximum PV Array Power | 5000W(10000W for 200A optional) 2000W 1000W 2000W |
||||
MPPT Range @ Operating Voltage | 64~145VDC | ||||
Standby Power Consumption | <2W | ||||
MECHANICAL SPECIFICATIONS | Machine Dimensions(W*H*D)(mm) | 670*410*215mm 322*486*134 309*505*147 309*505*147 |
|||
Package Dimensions(W*H*D)(mm) | 884*618*443mm 426*560*260.5 375*655*269 375*655*269 |
||||
Net Weight(kg) | 69+2.5 | 75.75+2.5 | |||
Gross Weight(kg) | 82.5+2.5 | 89+2.5 | |||
OTHER | Audible Noise | 60dB MAX | |||
Display | LED+LCD | ||||
Operating Temperature | 0°C~40°C | ||||
Storage Temperature | -15°C -60°C |