1KW and 1.5W Single Phase Inverter Single Phase Grid Inverter Solar Inverter
Description:
U-SPI inverter has following characteristics which make U-SPI inverter “High Efficiency, High Reliability, High Cost Effective Ratio” . Wide DC input voltage and current ranges, enables more PV panels connected. Wide MPP voltage range ensure high yield under various weather conditions. High MPP tracking accuracy, ensure the minimum power loses during converting. Complete set of protection methods. Also, following protection methods are integrated in U-SPI inverter: Internal overvoltage, DC insulation monitoring, Ground fault protection, Grid monitoring, Ground fault current monitoring, DC current monitoring, Integrated DC switch.
Features:
Product Details:
Input(DC) | ||
Max. PV Module Power [W] | 1250 | 1750 |
Max. Input Power [W] | 1200 | 1700 |
Max. DC Voltage [V] | 500 | 500 |
Nominal DC Voltage [V] | 360 | 360 |
Operating MPPT Voltage Range [V] | 60 - 400 | 60 - 400 |
MPPT Voltage Range at Nominal Power [V] | 155 - 400 | 155 - 400 |
Start up DC Voltage [V] | 70 | 70 |
Turn off DC Voltage [V] | 50 | 50 |
Max. DC Current[A] | 10 | 10 |
Max. Short Circuit Current [A] | 12 | 12 |
Number of MPP trackers | 1 | 1 |
Number of DC Connection | 1 | 1 |
DC Connection Type | Amphenol Connector | Amphenol Connector |
Output(AC) | ||
Max. AC Appaeent Power [VA] | 1000 | 1500 |
Nominal AC Power [W] | 1000 | 1500 |
Nominal Grid Voltage [V] | 220 / 230 / 240 | 220 / 230 / 240 |
Nominal Grid Frequency [Hz] | 50 / 60 | 50 / 60 |
Max. AC Current [A] | 5 | 7.5 |
Grid Voltage Range [V]* | 185 - 276 | 185 - 276 |
Grid Frequency Range [Hz]* | 45 - 55 / 55 - 65 | 45 - 55 / 55 - 65 |
Power Factor | 0.9i - 0.9c | 0.9i - 0.9c |
Total Harmonic Distortion (THD) | <3% | <3% |
Night time Power Consumption [W] | <1 | <1 |
AC Connection Type | Plug-in connector | Plug-in connector |
Efficiency | ||
Max. Efficiency | 96.5% | 96.5% |
Euro Efficiency | 95.8% | 96.0% |
MPPT Efficiency | 99.9% | 99.9% |
Safety and Protection | ||
Protection Functions | Array ground insulation resistance monitoring / Output over current protection / Residual current monitoring / Array polarity reverse protection / Output over/under voltage protection / Surge protection / Array over voltage protection / Output over/under frequency protection / Anti-island protection / Array over current protection / Output short circuit protection / Over temperature protection | |
Protection Class | Ⅰ(According to IEC 62103) | |
Overvoltage Category | PV Ⅱ / Mains Ⅲ(According to IEC 62109-1) | |
Reference Standard | ||
Safety Standard | IEC/EN 62109-1,IEC/EN 62109-2 | |
EMC Standard | EN 61000-6-1,EN61000-6-3,EN 61000-6-2,EN61000-6-4,EN61000-3-2,EN 61000-3-3 | |
Grid Standard | VDE-AR-N 4105, VDE 0126-1-1, C10/11,G83/2, UTE C 15-721-1, CEI 0-21, EN50438, NB/T32004, IEC62116, IEC61727, IEC61683, IEC60068 | |
Physical Structure | ||
Dimensions (WxHxD) [mm] | 210 * 290 * 90 | |
Weight [kg] | 5 | |
Environmental Protection Rating | IP 65(According to IEC 60529) | |
Cooling Concept | Natural convection | |
Mounting Information | Wall bracket | |
General Data | ||
Operating Temperature Range [℃] | -25 to +60(derating above 45℃) | |
Relative Humidity | 0% to 100%,no condensation | |
Max. Altitude (above sea level) [m] | 2000 | |
Noise Level [dB] | <40 | |
Isolation Type | Transformerless | |
Display | 2 LED,Backlight,2 * 16 Character LCD | |
Data Communication Interfaces | RS485 / WiFi / GPRS optional | |
Guarantee | 5 - 25 years optional | |
*The AC voltage and frequency range may vary depending on specific country grid |