1XN 2XN PLC Fiber Optic Splitter Steel tube / ABS Cassette / Rack Mount Type Optional
Sopto provides single-mode Planar Lightware Circuit Splitter (PLC type), Steel tube splitter, ABS Cassette,Plugin splitter or Tray type,Rack Mount type fiber PLC splitters. Single-mode Planar Lightware Circuit Splitter (PLC type) are developed based on unique silica glass waveguide process with reliable precision aligned fiber pigtail in a miniature package, it provides a low-cost light distribution solution with small form factor and high reliability. The PLC type devices have high performance in terms of low insertion loss, low PDL high return loss and excellent uniformity over a wide wavelength range from 1260nm to 1650nm and working in temperature from -40C to +85C. The PLCS devices have standard configurations of 1x4, 1x8, 1x16 and 1x32 configurations, as well as customized structures of 2x8, 2x16, 2x32 and 2x64.
• Steel tube splitter is a kind of ODN product suitable for PON networks that can be installed in the pigtail cassette, test instrument and WDM system, which minimizes the space occupation. It is relatively fragile on fiber protection and need a complete protection design on carrying box body and device.
• ABS Cassette,Plugin splitter or Tray type is most commonly used in the PON networks. It provides the complete protection for inner optical components and cable, as well as designed for the convenient and reliable installation, but its volume is relatively large. It's mainly used for various connection and distribution products(outdoor fiber distribution box) or network cabinets. splitter is most commonly used in the PON networks. It provides the complete protection for inner optical components and cable, as well as designed for the convenient and reliable installation, but its volume is relatively large. It's mainly used for various connection and distribution products(outdoor fiber distribution box) or network cabinets.
• Rack Mount type fiber PLC splitters are all with superior optical performance, high stability and high reliability to meet various application requirements.
Features
● Compact design
● Low insertion loss and low PDL
● High reliability
● High channel counts
● Wide wavelength range
● Large operating temperature range
● Customized packaging and configuration
1XN PLC Steel Tube Specifications:
Port Configuration
| 1X2 | 1X4 | 1X8 | 1X16 | 1X32 | 1X64 | 1X128 | |
Fiber Type | SMF-28e or Customer specified | |||||||
Operating Wavelength (nm) | 1260~1650 | |||||||
Insertion Loss (dB) | PLC Device | ≤3.8 | ≤7.4 | ≤10.5 | ≤13.5 | ≤16.8 | ≤20.5 | ≤24 |
PLC Plug type | ≤4.2 | ≤7.8 | ≤10.9 | ≤13.9 | ≤17.2 | ≤20.9 | ≤24.4 | |
PLCAdaptor type | ≤4.4 | ≤8.0 | ≤11.1 | ≤14.1 | ≤17.4 | ≤21.1 | ≤24.6 | |
Polarization Dependent Loss (dB) | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.5 | |
Loss Uniformity (dB) | Fixed working wavelength | ≤0.6 | ≤0.7 | ≤1.0 | ≤1.2 | ≤1.5 | ≤2.0 | ≤2.5 |
Full working bandwidth | ≤1.1 | ≤1.2 | ≤1.5 | ≤1.7 | ≤2.0 | ≤2.5 | ≤3.0 | |
Return Loss (dB) | PLC Device | ≥55 | ||||||
PLC Plug type | ≥45(PC); ≥50(UPC);≥55(APC); | |||||||
Directivity(dB) | ≥55 | |||||||
Temperature Dependent Loss(°C ) | -40~+85C | |||||||
Notes | The test wavelengths of insertion loss in the table are: 1310nm, 1490nm, 1550nm, and the insertion loss in the 1260nm-1300m and 1600nm-1650nm wavelength range increases 0.3dB on the basis of the above index. The test wavelengths of Loss Uniformity in the table are: 1310nm, 1490nm, 1550nm. The channel uniformity index in the1260nm-1300nm and 1600nm-1650nm wavelength range increases 0.5dB based on the above index. |
Notes: 1. Specifications without fiber connectors. 2. Room temperature test.
2XN Steel Tube PLC Specifications:
Port Configuration
| 2X2 | 2X4 | 2X8 | 2X16 | 2X32 | 2X64 | 2X128 | |
Fiber Type | SMF-28e or Customer specified | |||||||
Operating Wavelength(nm) | 1260~1650 | |||||||
Insertion Loss (dB) | PLC Device | ≤4.0 | ≤7.6 | ≤10.8 | ≤13.8 | ≤17.1 | ≤20.8 | ≤24.3 |
PLC Plug type | ≤4.4 | ≤8.0 | ≤11.2 | ≤14.2 | ≤17.5 | ≤21.2 | ≤24.7 | |
PLC Adaptor type | ≤4.6 | ≤8.2 | ≤11.4 | ≤14.4 | ≤17.7 | ≤21.4 | ≤24.9 | |
Polarization Dependent Loss (dB) | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.5 | |
Loss Uniformity (dB) | Fixed working wavelength | ≤0.6 | ≤0.7 | ≤1.0 | ≤1.2 | ≤1.5 | ≤2.0 | ≤2.5 |
Full working bandwidth | ≤1.1 | ≤1.2 | ≤1.5 | ≤1.7 | ≤2.0 | ≤2.5 | ≤3.0 | |
Return Loss (dB) | PLC Device | ≥55 | ||||||
PLC Plug type | ≥45(PC); ≥50(UPC);≥55(APC); | |||||||
Directivity(dB) | ≥55 | |||||||
Temperature Dependent Loss (°C ) | -40~+85C | |||||||
Notes | The test wavelengths of insertion loss in the table are: 1310nm, 1490nm, 1550nm, and the insertion loss in the 1260nm-1300m and 1600nm-1650nm wavelength range increases 0.3dB on the basis of the above index. The test wavelengths of Loss Uniformity in the table are: 1310nm, 1490nm, 1550nm. The channel uniformity index in the 1260nm-1300nm and 1600nm-1650nm wavelength range increases 0.5dB based on the above index. |
Notes: 1. Specifications without fiber connectors. 2. Room temperature test.
Compliance
● Telcordia GR-1209-CORE
● Telcordia GR-1221-CORE
Application
● FTTx systems
● LAN,WAN and Metro Networks
● Analog/Digital Passive Optical Networks
● CATV Networks
● Other applications in fiber optical systems
Ordering Information
Part Number:SPS-2×16-A1-09-1 S S U- B P 1 2 3 4 5 6 7 8 910 | |
1 - Input Number | 1;2 |
2 - Output Number | 2;4;8;16;32;64;128etc |
3 - Fiber Type | D:G.652D;A1:G.657.A1;A2:G.657.A2;M:Customized Fiber Type |
4 - Diameter | 25:250μm;09:0.9mm (with Loose Tube );20:2.0mm;30:3.0mm;I:built-in |
5 - Length | 05:0.5M;1:1M;15:1.5Metc |
6 - Input Connector | 【Null】:No Input Connector;L:LC;S:SC;F:FC |
7 - Output Connector | 【Null】:No Input Connector;L:LC;S:SC;F:FC |
8 - Connector Endface | U:UPC;A:APC;P:PC |
9 - Package | B:Steel Tube;P:Plugin;A:ABS Cassette;T:Tray;R:Rack Fixed |
10 - Type | P:PLC |