On / off Grid Hybrid solar energy inverter 4kva 4000w with 80A MPPT Controller
Hybrid Solar Inverter Quick Detailes
1 .On-Off Grid Hybrid Solar Power Inverter
2. High Frequency Pure Sine Wave Output
3. Parallel Function for 3KVA/4KVA/5KVA
4. Power Supply from PV/Battery/Grid
5. Inbuilt 80A/120A MPPT Solar Charge Controller
6.LCD Display the Load,PV,Grid and Battery Detaile in Real-time
Hybrid Solar Inverter Key Features
1. Parallel operation up to 6 units only for 3KVA-5KVA
2. Power Supply for Self-consumption and Feed-back to the grid
3. Programmable supply priority for PV, Battery or Grid
4. Adjustable Charging current and voltage for Users
5. Multi-communications port :RS232/USB/Dry -Contact
6. Programmable multiple operation modes: Grid-tie,off-grid and grid-tie with backup
.
SSP3119C On-Off Grid Hybrid Solar Power Inverter technical specifications:
MODEL | 1K-12 | 2K-24 | 3K-48 | 4K-48 | 5K-48 |
Max.PV Array Power | 1000W | 2000W | 4000W | 4000W | 6000W |
Rated Output Power | 1000W | 2000W | 3000W | 4000W | 5000W |
Maximum PV Array Open Circuit Voltage | 145VDC | 145VDC | 145VDC | 145VDC | 145VDC |
MPPT Range @ Operating Voltage | 15~115VDC | 30~115VDC | 60~115VDC | 60~115VDC | 60~115VDC |
MPPT Tracker Number | 1 | 1 | 1 | 1 | 2 |
GRID-TIE OPERATION | |||||
GRID OUTPUT(AC) | |||||
Nominal Output Voltage | 220/230/240VAC | ||||
Output Voltage Range | 184-264.5VAC | ||||
Nominal Output Current | 4.3A | 8.7A | 13A | 17.4A | 21.7A |
Power Factor | >0.99 | ||||
Efficiency | |||||
Maximum Conversion Efficiency (DC/AC) | 90% | ||||
GRID INPUT | |||||
Accepatable Input Voltage Range | 90-280VAC or 170-280VAC | ||||
Frequency Range | 50HZ/60HZ(Auto sensing) | ||||
Maximum AC Input Current | 30A | 40A | |||
BATTERY MODE OUTPUT(AC) | |||||
Nominal Output Voltage | 220/230/240VAC | ||||
Output Waveform | Pure Sine Wave | ||||
Efficiency(DC to AC) | 93% | ||||
BATTERY&CHARGER | |||||
Nominal DC Voltage | 12VDC | 24VDC | 48VDC | 48VDC | 48VDC |
Maximum Solar Charge Current | 80A | 80A | 80A | 80A | 120A |
Maximum AC Charge Current | 60A | ||||
Maximum Charge Current | 140A | 140A | 140A | 140A | 180A |
INTERFACE | |||||
Parallel Function | N/A | N/A | Yes | Yes | Yes |
Communication | USB or RS232/Dry-Contact | ||||
ENVIRONMENT | |||||
Humidity | 0~90%RH (No condensing) | ||||
Operating Temperature | 0 to 50℃ |
Protection Function
-Low battery voltage
-Over load
-Output short circuit
-Over- temperature
-Restrain surge interference,
-Eliminate noise
-Protection for thunder striking,provide the reliable power to the home appliances.
Typical Application
Supply the reliable long back up time power for the TV,Computer,DVD,VCD, Printing machines,Data center, Financial and Securities, Large Data rooms,Power tools, lawn mowers, vacuum cleaners,Cameras and photographic equipment etc