Suitable for
For GOLDWAY REDEL 5 PIN ADULT
Cable length is 3.0 Meter
Suitable for UT4000; AnKe: 553; Biolight, Cheersails: CSM-2000, Choice Electronics MMED6000DP, WanDong, Jumbor: JB9101/9105/9107, TianRong, BaoZhong, HongRunDa: EM-6, QiLan: M-III, JERRY: PM200, JoyceTracker: BMD-50, Mindray: PM9000; Richer: RC9000, ShenMai: KP-900; Spurt: CP-1200; SHIPAI: KMI-1000; ZhongHengSheng: KD580; ZhongYuan: HD-2000
http://www.spo2-ecg.com
Goldway UT4000A, UT4000C, UT4000E,UT4000F,
UT4000Apro,UT4000Fpro, UT6000A
OEM P/N | Part No. | Description(Cable & Connector) |
GWA0001 | Cable,8ft, 5pin(1bit)>DB9F,BCI | |
![]() | ![]() ![]() |
Goldway UT4000A, UT4000C;4000B PACE TECH
OEM P/N | Part No. | Description(Cable & Connector) |
GWA0002 | 8ft,Readel 1bit(single).5pin>DB9F,BCI | |
![]() ![]() | ![]() |
can be used for Goldway monitors with high actuary and fast data.
OEM P/N | Part No. | Description(Cable & Connector) |
GWA0003 | 8ft,Readel 7pin(2bit)>>DB9F,BCI | |
![]() ![]() | ![]() |
TECHNICAL PARAMETERS:
LEDS | Red | 660nm normal |
Infrared | 880 / 905 / 940nm normal | |
Test Range | Oxygen Saturation(%SpO2) | 0 % to 100 % |
Pulse Rate(bpm) | 30 to 245 | |
Accuracy | SpO2 | ± 2%(90% -1 00 %) |
±3%(70%-89 %) | ||
unspecified(0-69 %) | ||
Pulse Rate | ±1 bpm(30 - 59bpm) | |
±2 bpm(60 - 149bmp) | ||
±3 bpm(150 - 245bmp) | ||
Storage and Transport Environment | - 10°C~ + 40°C | |
Operating Temperature | + 5°C~ + 40°C | |
Operating/Storage/Transportation humidity | 0% - 80% | |
Hyperbaric pressure | 86kPa - 106 kPa |
Products more details
1. Adult finger clip type spo2 sensor
Such blood oxygen probe, sensor acquires signal on adult fingers, the hard plastic shell for fixed sensors is larger and fits adult measurement, the instruments of different brand its probe shell may be slightly different, different shell shape cannot influence the performance of product.
2. Pediatric finger clip type spo2 sensor
Such blood oxygen probes, sensors in children's fingers acquisition signal, the hard plastic shell used in fixed sensor is smaller and measurements are suitable for children.
3. Adult Soft Tip type spo2 sensor./soft rubber/soft silicone tip
Such blood oxygen probe, sensor covered on adult finger to collect signals, the soft gel coat used in fixed sensors is bigger, suitable for adults. Different brands of instruments and its probe coat may be slightly different, different shape of coat cannot influence the product performance.
4. Neonatal wrap spo2 sensor or"Y" type wrap spo2 sensor.
The type of blood oxygen sensor, the sensor wrapped in neonatal acquisition signals on his foot, fixed sensors used in soft gel coat is bind package type, suitable for newborns.