Siemens Reusable SpO2 Sensor Probe for adult Machine Sensor Finger Soft Adult Patient Suit
Manufacturer | Model |
---|---|
Draeger | Infinity Delta, Infinity Delta XL, Infinity Gamma, Infinity Gamma X, Infinity Gamma XL, Infinity Kappa, Infinity Kappa XLT, Infinity Vista, Infinity Vista XL, SC 6000, SC 6002XL, SC 7000, SC 8000, SC 9000, SC 9000X |
Specifications
Rating: The basic unit operates at a rating of 3.75V with a tolerance of +/-10%.
Safety Category: The basic unit is classified as a BF type, indicating the level of electrical safety provided by the device.
Waterproof Category: The basic unit has an IPX2 waterproof rating. This means it is protected against water splashes from any direction at an angle of up to 15 degrees.
Service Life: The expected service life of the basic unit is 1 year. This indicates the duration during which the device is designed to operate optimally.
Shelf-Life: The shelf-life of the basic unit is 3 years. This refers to the period during which the device can be stored in appropriate conditions and still retain its functionality and performance.
Equipment:
For the cleaning, disinfection, or sterilization of SpO2 sensors and their connecting cables in departments where sterility levels are required, Med Accessories recommends the following methods:
Cleaning:
Clean the sensor and connecting cable with warm soapy water or 70% isopropyl alcohol.
Use a soft cloth or sponge to gently clean the surface.
Rinse thoroughly with water and allow them to dry completely before use.
Disinfection:
Med Accessories recommends following the disinfection guidelines provided by your healthcare facility or local regulations.
Disinfection methods may include using disinfectant wipes or solutions recommended for medical equipment.
Ensure that the disinfectant is compatible with the materials of the sensor and cable.
Follow the instructions provided by the disinfectant manufacturer and allow sufficient contact time for effective disinfection.
Rinse the sensor and cable thoroughly with water after disinfection and allow them to dry completely before use.
Sterilization:
Med Accessories does not recommend sterilizing the SpO2 sensors and connecting cables.
Sterilization methods such as autoclaving or other high-heat sterilization techniques can damage the sensor and cable.
It's important to perform regular visual inspections of the sensor and cable, checking for any mechanical or electrical defects. If any defects are found, do not use the sensor and cable and discard them appropriately.
The specified operating conditions for the SpO2 sensor and cable include an ambient temperature range of 0°C to +40°C, relative humidity range of 0% to 80%, and atmospheric pressure range of 860 to 1060 HPa.