Specifications
Place of Origin :
China
Brand Name :
Med Accessories
Model Number :
M69 series
Packaging Details :
1pcs/bag
Certification :
CE,ISO,SFDA
Delivery Time :
About one week
Payment Terms :
T/T
MOQ :
1pcs
Category :
Reusable spo2 sensor
Cable Length :
3 meters
Material :
TPU
Cable Color :
GREY
SpO2 Technology :
Nellcor
Latex-free :
Yes
Description

Compatible Nelllcor Adult soft Direct-Connect SpO2 Sensor

Compatible
Manufacturer Model
Bitmos
sat 800, sat 801, sat 805, sat 816, satPuls
CAS Med
511, 740
Cardio Aid
200
Covidien > Nellcor
N-3000, N-395, N-390, N-560, N-550,N-595, N-6000, N-600, N-600x, NPB-290, NPB-295, Oximeters that require Nellcor OxiMax sensors, Symphony N-3000
Criticare
506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506N3, 506NV3, 506NVP3
DRE
Waveline
Datex Ohmeda
Cardiocap/5, enGuard CM5
Digicare
LW600
Fukuda Denshi
Dynascope DS-7100
GE Healthcare > Critikon > Dinamap
Carescape B650, Carescape V100, E-NSAT, M-NSAT Modules, Pro 1000, Pro 1000 V3, Pro 200, Pro 300, Pro 300V2, Pro 400, Pro Series, Pro Series V2, ProCare, ProCare 200, ProCare 300, ProCare 400, ProCare Ausculatory 400, ProSeries V2, V300
Huntleigh
All
Invivo
Escort II OPT30 Prism, MDE Escort Prism, T8
Mediana
M30, YM6000
Midmark > Cardell
9403, 9500HD
Mindray > Datascope
Accutor V, Accutorr Plus, Accutorr Plus (Nellcor), Accutorr V, Duo, EPM4, Passport 2, Passport 2LT, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, V-Series, V12, V21
Nihon Kohden
BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100
Omron > Colin
BP-306, BP-508, BP-808, BP-88, BP-88S, BP-S510, Press-Mate, T105NXM
Oridion
Capnostream 20

Equipment: * Connect the sensor cable to the appropriate device (pulse oximeter) * Turn on the device and check correct operation by consulting the monitor's operating instructions. *To ensure proper operation of the monitor, please connect and disconnect the sensor cable from the monitor cable. Use correctly and safely
The sensor and its connecting cable require system inspection at least once or more per month, depending on frequency of use and sanitization of the cable *Visual inspection (appearance of insulator, connector contact pins, etc.) *Verification of mechanical integrity of the connector Do not use and discard any sensor with mechanical or electrical defects. The operating conditions of the SpO2 sensor and its cable are as follows: *Ambient temperature: 0° to +40° C
*Relative humidity: 0 to 80%
*Atmospheric pressure: 860 to 1060 HPa For use of SpO2 sensors and their connecting cables in departments where compliance with sterility levels is required, Med Accessories recommends the following cleaning, disinfection or sterilization methods:

Cleaning equipment: Clean the sensor and its connecting cable with warm soapy water. The probe and cable must be cleaned with a soft cloth moistened with soapy water or 70% isopropyl alcohol. Be careful to avoid damage
Visual indicators and detector surfaces. Allow the probe and cable to dry thoroughly before use. Do not use any abrasives or chemicals other than 70% isopropyl alcohol
Do not irradiate, autoclave, soak, or immerse the probe in any type of solution. Keep the probe clean and dry. Under the conditions of use advocated in these operating instructions, the average life expectancy of the SpO2 sensor is more than one year.

During the Warranty Period: Med Accessories offers a warranty on its products that includes replacement for any quality-related issues that arise within the specified warranty period. This warranty applies to normal conditions of use. If a quality issue occurs during the warranty period, Med Accessories will provide replacement service to correct the problem.

Compatibility Guarantee: Med Accessories understands the importance of compatibility between its products and the devices with which they are intended to be used. If after purchasing a Med Accessories product it is discovered that the product is incompatible with the specific device for which it was intended, Med Accessories will take immediate action. They will provide a new replacement that is compatible with the customer's device or provide a refund on the purchase.

Send your message to this supplier
Send Now

Stable TPU Spo2 Sensor Probe , Portable Finger Clip Pulse Oximeter

Ask Latest Price
Watch Video
Place of Origin :
China
Brand Name :
Med Accessories
Model Number :
M69 series
Packaging Details :
1pcs/bag
Certification :
CE,ISO,SFDA
Delivery Time :
About one week
Contact Supplier
video
Stable TPU Spo2 Sensor Probe , Portable Finger Clip Pulse Oximeter
Stable TPU Spo2 Sensor Probe , Portable Finger Clip Pulse Oximeter
Stable TPU Spo2 Sensor Probe , Portable Finger Clip Pulse Oximeter

Med Accessories Technology Dongguan Co., Ltd.

Verified Supplier
2 Years
guangdong, dongguan
Since 2018
Business Type :
Manufacturer
Total Annual :
1000000-5000000
Employee Number :
100~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement