Manufacturer | Model |
---|---|
Advanced Instrumentations | PM1000F |
AnKe | 553 |
Beijing Choice Electronic | MMED6000DP |
Cheersails | CSM-2000 |
Comen | Star5000 |
General Meditech Inc. | G3D |
Goldway | UT4000, UT4000A, UT4000F, Vet 420A |
Heal Force | Prince 180D |
Hillmed | HM-EXRP3, Monitors with BCI SpO2 Technology |
HongRunDa | EM-6 |
JERRY | PM200 |
JoyceTracker | BMD-50 |
Jumbor | JB9101/9105/9107 |
Mediblu | MM12 |
Mindray > Datascope | PM9000 |
QiLan | M-III |
Richer | RC9000 |
SHIPAI | KMI-1000 |
ShenMai | KP-900 |
Spurt | CP-1200 |
Venni | VI-1040P |
Waltvick | Zafiro W AL0408 |
ZhongHengSheng | KD580 |
ZhongYuan | HD-2000 |
Original HP part number:
M37A10 Adult finger 3.0m
1. Adult finger clip. Application:Adult>41KG. Application site:Index or other finger
2. Pediatric finger clip. Application:Pediatric>11-41KG. Application site:Index or other finger
3. Adult silicone. Application:Adult>41KG. Application site:Index or other finger
4. Pediatric silicone. Application:Pediatric>11-41.1KG. Application site:Index or other finger
5. Infant silicone wrap. Application:Neonate 1-4.0KG;Infant 3-15KG;Pediatric>10-40KG. Application site:Pediatric-Index or other finger;Neonate-foot;Infant-great toe
6. Adult ear clip. Application:Adult>40.1KG. Application site:Ear
Warning:Only use for pulse oximeter which has autoconditioning power function.
7. Animal Spo2 sensor. Application:Dog, Cat. Application site:ear,tongue.
Warning: Only use for animal pulse oximeter or pulse oximeter which has autoconditioning power function.
8. Disposable blood oxygen sensor: Disposable blood oxygen sensor for adults and infants.
Process flow
1. Wire cutting-- 2. Sheath stripping-- 3. Shield twisting-- 4. Sleeve crimping-- 5. Welding-- 6. Crimping end-- 7. Rubber shell-- 8. Electrical test -- 9. Inner molding -- 10. External molding -- 11. Appearance inspection -- 12. Electrical test -- 13. Network threaded end -- 14. Sheath tripping -- 15. Shield twisting -- - 16. Soldering-- - 17. Chip soldering-- 18. Dispensing--19. Assembly-- 20. Final test-- 21. Packaging
Feature:
1. TPU polymer wire skin is resistant to high temperatures and corrosion, and is convenient for high-temperature alcohol disinfection.
2. The outer alloy shielding layer is tightly compacted to prevent physiological signals from being interfered with.
3. Use dual-wavelength diodes and silicon microelectrodes from American Life Discoverer Co., Ltd. to ensure that the values are more accurate and sensitive, and the output is still clear under the minimum perfusion condition of 0.025.