Stainless Steel 304 Pass Through Autoclave With HMI Control System
Key Features
Description
Each of our pass-through sterilizers is custom built. The control panel can be mounted either
inside or outside the containment area (depending on the application), as can any data ports or the hardware printer.
Pressure interlocks, thermal safety locks, and double door interlock mechanisms prevent any inadvertent cycle disruptions or breaching of containment integrity.
Main Parameters
Model | Chamber Size | Overall Size | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg/cycle | Kg/cycle | KVA | |
MDB-0.24 | 600*600*670 | 1500*1800*1010 | 20 | 30 | 2 |
MDB-0.36 | 600*600*1000 | 1500*1800*1340 | 25 | 40 | 2 |
MDB-0.6 | 610*910*1170 | 1500*1900*1510 | 30 | 60 | 3 |
MDB-0.8 | 610*910*1450 | 1500*1900*1790 | 35 | 80 | 3 |
MDB-1.0 | 680*1180*1250 | 1600*2000*1590 | 40 | 100 | 4 |
MDB-1.2 | 680*1180*1500 | 1600*2000*1840 | 45 | 120 | 4 |
MDB-1.5 | 680*1180*1870 | 1600*2000*2210 | 50 | 150 | 4.5 |
MDB-2.0 | 1000*1200*1700 | 2000*2000*2040 | 60 | 200 | 4.5 |
MDB-3.0 | 1000*1500*2000 | 2000*2200*2340 | 90 | 300 | 5 |
MDB-4.0 | 1000*1500*2670 | 2000*2200*3010 | 120 | 400 | 6 |
MDB-5.0 | 1000*1500*3340 | 2000*2200*3680 | 150 | 500 | 8 |
MDB-6.0 | 1000*1500*4000 | 2000*2200*4340 | 180 | 600 | 8 |
MDB-8.0 | 1000*1500*5340 | 2000*2200*5680 | 240 | 800 | 12 |
Materials
Chamber | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Jacket | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
| |
Door internal side | STEEL |
|
304 L stainless steel | STANDARD | |
316 L stainless steel |
|
Applications
These sterilizers are designed for the sterilization of solid and porous biological products like filters, sealing gaskets, empty containers, textiles and clothing, rubber stoppers, machine and system components.
We Are The Difference
Easy Maintenance
Medpharm steam sterilizers are designed for easy maintenance and servicing. All of the assemblies and the control system are secured in a separate maintenance compartment, which is easily accessible.
This is an important aspect for shorter maintenance and servicing times.
Maximum Accessibility
Designed for the pharmaceutical industry, the engineering and the quality of the materials and components used meet the most stringent demands with regard to reliability and long service life.
The goal is to always ensure maximum system accessibility while constantly complying with all required specifications.
Brochure load down from here
Medpharm medical large steam autoclave brochure.pdf