Automatic Prevacuum Steam Sterilizer With Automatic Low Water Protection
Features
• Plate or car and trolley loading system
• Automatic door interlock system
• Pre-vacuum air steam sterilization
• Optional advanced control system with touch screen control
• 0.22u air filter
Size Table
Model | Chamber Size | Overall Size | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg/cycle | Kg/cycle | KVA | |
MD-0.20V | 400*400*1300 | 1000*1800*1640 | 18 | 22 | 2 |
MD-0.24V | 600*600*670 | 1200*2000*1010 | 20 | 30 | 2 |
MD-0.30V | 600*600*840 | 1200*2000*1180 | 22 | 35 | 2 |
MD-0.36V | 600*600*1000 | 1200*2000*1340 | 25 | 40 | 2 |
MD-0.45V | 600*600*1250 | 1200*2000*1590 | 27 | 50 | 2 |
MD-0.60V | 600*600*1670 | 1200*2000*2010 | 30 | 60 | 3 |
Autoclave Safety
Door Safety
• Chamber door cannot be opened when chamber is pressurized
• Steam cannot enter the chamber when the door is open
• A cycle cannot start if the door is open or not properly locked
• Sliding door movement is stopped if an object is detected in front of the door
Safety Valves
• Both chamber and jacket are equipped with pressure relief valves to prevent excess pressure.
Steam Supply
• Saturated steam can be supplied to the autoclave from building steam, a stand-alone generator, or a built-in generator.
Emergency Shut-Off
• Easily accessible emergency switches for immediate cycle shut-off.
• Digital and mechanical monitoring systems provide accurate pressure results.
Description
Strong Vacuum Pump
The built-in vacuum pump produces a strong vacuum that ensures proper air removal for excellent sterilization results.
Inactivation of Micro-organisms
After sterilization the number of micro-organisms are reduced to less than 10-6.
Fast Cooling for Fast Cycles
Fast cycles are an important factor that influences the waste processing time. A built-in cooling
coil is an important feature that reduces cycle cooling times enabling higher cycle rates and empowering you to sterilize medical waste without delays.
Specialized Loading Cart for Waste Transfer
A specialized loading cart for safely transferring medical waste is available with the following
important features:
• The bottom shelf has no holes to prevent liquid from leaking out of the cart
• The bottom shelf has a drain to enable collection of any liquid waste into a container
• All the shelves have a barrier around their perimeter to prevent waste from falling off the cart
Flexible PT100 for Liquid Loads
When treating blood, urine and other liquid medical waste a flexible PT100 placed in liquid waste
load ensures sterilization at an effective sterilization temperature.
Prevacuum Air Sterilization
All air that leaves the chamber prior to sterilization is treated as highly infectious and passes
through a stringent biological decontamination system that renders the air sterile.