With High Temperature Over Shoot Alarm Steam Autoclave Sterilizer Machine For Mushroom Farm
Main Parameters
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-0.8Y | 680*1180*1000 | 2200*2000*1410 | 1480 | 35 | 80 | 3 |
MD-1.0Y | 680*1180*1250 | 2200*2000*1660 | 1630 | 40 | 100 | 4 |
MD-1.2Y | 680*1180*1500 | 2200*2000*1910 | 2030 | 45 | 120 | 4 |
MD-1.5Y | 680*1180*1870 | 2200*2000*2280 | 2230 | 50 | 150 | 4.5 |
MD-2.0Y | 1000*1200*1700 | 2800*2000*2110 | 2490 | 60 | 200 | 4.5 |
MD-3.0Y | 1000*1500*2000 | 2800*2200*2410 | 3050 | 90 | 300 | 5 |
MD-4.0Y | 1000*1500*2670 | 2800*2200*3080 | 3700 | 120 | 400 | 6 |
MD-5.0Y | 1000*1500*3340 | 2800*2200*3750 | 4600 | 150 | 500 | 8 |
MD-6.0Y | 1000*1500*4000 | 2800*2200*4410 | 5400 | 180 | 600 | 8 |
MD-8.0Y | 1000*1500*5340 | 2800*2200*5750 | 7000 | 240 | 800 | 12 |
Safety Door
1. There are two types of automatic doors: hinge and level-moving door.
2. Put the place of this device shall be the hard concrete floor.
3. Mushroom autoclave machine has safety interlocking device.
When the pressure inside the sterilizer is higher than safe pressure, the door can not be opened.
The two doors have an interlock function.And the seal groove of door is on the body of sterilizer,the kind of design is safe, reliable and pneumatic-tight.
Description
A sterile technique is of utmost importance in mushroom home cultivation. A pressure cooker is needed to sterilize your substrates and casing material. Also some supplies like scalpels can be sterilized in a pressure mushroom autoclave sterilizer machine.
Special notes for the mushroom sterilization
- Inspect the articles, supplies, jars and bags which you are going to sterilize. Check that they
are clean and in a good, working condition.
- Wrap all the articles and supplies in a double layer of tinfoil.
- Cover the jars and boxes with a double layer of tinfoil.
- Jars with no holes in the lids and/or no filter whatsoever may never be closed for 100% airtight.
The up building pressure during sterilization is in that case not able to escape.
- Keep an eye on the mushroom autoclave sterilizer machine during sterilization.
- And again: read and follow the safety instructions that come with mushroom autoclave sterilizer machine.
- When the mushroom autoclave sterilizer machine is closed and put on the stove it will start to
build up steam. When the mushroom autoclave sterilizer machine has reached 15 psi, the right
temperature has been reached for some times.
- Be aware that when you have to sterilize something for a certain period count down starts from
this moment, not start from using the sterilizer
Applications
Cultivating mushrooms in containers
Competitive Advantage
No second pollution and can kill all lives.