Copper Alloy Steel C12200 C70600 For Heat Exchanger Bundle With Tubesheet
Tube Bundle: The collection of tubes, tube sheets, and baffles is often referred to as the tube bundle. It is the core heat transfer section of the heat exchanger, and it can be removed for maintenance and cleaning purposes.:
Standards | ||||||
Cupro Nickel Tube90/ 10 | Standard | BS2871part3 | ASTM B-111 | IS 1545 | JIS H 3300 | NFA 51 102 |
Symbol | CN 102 | C 70600 | CuNi10Fe1 | C7060 | CuNi10Fe1Mn | |
Cupro Nickel Tubes 70/30 | Standard | BS2871part3 | ASTM B-111 | IS 1545 | JIS H 3300 | NFA 51 102 |
NFA 51 102 | CN 107 | C 71500 | CuNi30Mn1Fe | C 7150 | CuNi30Mn1Fe |
Tube Sizes for Heat Exchangers & Condensers & Boiler | |||||||||
Outside Diameter | BWG | ||||||||
25 | 22 | 20 | 18 | 16 | 14 | 12 | 10 | ||
Wall Thickness mm | |||||||||
0.508 | 0.71 | 0.89 | 1.24 | 1.65 | 2.11 | 2.77 | 3.40 | ||
mm | inch | Weight kg/m | |||||||
6.35 | 1/4 | 0.081 | 0.109 | 0.133 | 0.174 | 0.212 | |||
9.53 | 3/8 | 0.126 | 0.157 | 0.193 | 0.257 | 0.356 | 0.429 | ||
12.7 | 1/2 | 0.214 | 0.263 | 0.356 | 0.457 | 0.612 | 0.754 | ||
15.88 | 5/8 | 0.271 | 0.334 | 0.455 | 0.588 | 0.796 | 0.995 | ||
19.05 | 3/4 | 0.327 | 0.405 | 0.553 | 0.729 | 0.895 | 1.236 | ||
25.4 | 1 | 0.44 | 0.546 | 0.75 | 0.981 | 1.234 | 1.574 | 2.05 | |
31.75 | 1 1/4 | 0.554 | 0.688 | 0.947 | 1.244 | 1.574 | 2.014 | 2.641 | |
38.1 | 1 1/2 | 0.667 | 0.832 | 1.144 | 1.514 | 1.904 | 2.454 | 3.233 | |
44.5 | 1 3/4 | 1.342 | 1.774 | 2.244 | 2.894 | 3.5 | |||
50.8 | 2 | 1.549 | 2.034 | 2.574 | 3.334 | 4.03 | |||
63.5 | 2 1/2 | 1.949 | 2.554 | 3.244 | 4.214 | 5.13 | |||
76.2 | 3 | 2.345 | 3.084 | 3.914 | 5.094 | 6.19 | |||
88.9 | 3 1/2 | 2.729 | 3.609 | 4.584 | 5.974 | 7.27 | |||
101.6 | 4 | 4.134 | 5.254 | 6.854 | 8.35 | ||||
114.3 | 4 1/2 | 4.654 | 5.924 | 7.734 | 9.43 |
Copper Nickel Tubes 90/10 for Heat Exchangers & Condensers
These Copper Nickel tubes & pipes for Heat Exchangers & Condensers are very important for all Industrial fields. The company has experience in these areas and is able to supply these tubes in accordance with most international standards and special customer requirements.
Size Range:
Production | Outside Diameter | Wall Thickness |
Heat Exchanger Tube | 6.00mm to 101.6mm | 0.5mm to 8mm |
Final Finishing
Solution Annealed & Pickled/Bright Annealed.
Type of Tubes:
U-bend & Straight.
Some of the quality tests carried out by us includes:
Corrosion Test | Conducted only when specially requested by the client |
Chemical Analysis | Test done as per required quality standards |
Destructive / Mechanical Testing | Tensile | Hardness | Flattening | Flare | Flange |
Reverse-bend and Re. flat tests | Carried out in full compliance with relevant standards & ASTM A-450 and A-530 norms, which ensures trouble-free expansion, welding & use at customers end |
Eddy Current Testing | Done to detect homogeneities in subsurface by using Digital Flaw-mark Testing System |
Hydrostatic Testing | 100% Hydrostatic Testing carried out according to ASTM-A 450 norms for checking tube leakage, and biggest pressure we can support 20Mpa/7s . |
Air Under Pressure Test | To check any evidence of air leakage |
Visual Inspection | After passivation, every single length of tubes & pipes is subjected to thorough visual inspection by trained staff for detecting surface flaws & other imperfections |
Supplementary Testing : Apart from the above mentioned tests, we also carry out on the manufactured products supplementary testing. The tests conducted under this include:
|
|
|