Specifications
Brand Name :
WINTEAM
Model Number :
YT-SXXXX
Certification :
ISO9001
Place of Origin :
CHINA
MOQ :
1 set
Price :
Negotiable
Supply Ability :
10set one month
Delivery Time :
30work days
Packaging Details :
wooden case
name :
Sterility Test Isolator
Type :
Sterility Testing Isolator
Air classification :
class A
Application :
Sterilization
Airflow direction :
Laminar flow
driven :
electric
Description

merck Millipore ss316 negative pressure isolator log6 for pharmaceutical industry

  • The soft cabin structure consisting of transparent PVC film is selected. The whole structure and operation platform are made of 316L stainless steel, and the top is closed.
  • Structural design, sterilization system, integrated control unit, air inlet and outlet system, air filtration unit, etc., more beautiful and easy to clean and maintain;
  • Siemens touch screen design, improve operator comfort.
  • the operating compartment 6 gloves standard operating port design, the main and secondary operating surfaces are 4, 2, respectively, the transmission compartment 4 gloves standard operating port design, no operation blind zone;
  • The sleeve is made of American material, and the airtightness, chemical compatibility and mechanical wear resistance are further improved;
  • Support two sterility test methods prescribed by the Pharmacopoeia: membrane filtration method and direct inoculation method.
  • the operation cabin, transfer cabin combination, can also be used alone, directly integrate the pump unit of the collection instrument to the operating platform;

Built-in intelligent bacteria collection instrument, can automatically pinch the tube, save internal operation time, and the isolator itself can work continuously, easy to operate, and shorten the sterilization time, etc., which saves you the overall inspection time and contributes to efficiency. . It has a fast sterilization cycle technology for airlock chambers, which meets the needs of continuous testing of large batches of multi-batch samples.

WINTEAM's new generation of sterility check isolators is a sealed system in which air is safely exchanged through a fan filter unit (High Efficiency Filter, HEPA) to achieve continuous control of particulates and microorganisms in the internal environment. When sealed, the internal surface has been biologically decontaminated. Use rapid transfer channels or air locks for aseptic transfer and transfer of materials to ensure protection between operators and drugs.

2,Parameter

Working power: AC220±22V 50HZ±1HZ
Power: 2500W
Internal lighting: ≥500Lux
noise: ≤65dB(A)
High efficiency filter: H14 grade filtration efficiency 99.995%
Kill rate: The ability to kill a thermophilic adipose spore is 106
Airflow model: Engineering turbulence
Pressure control range: 0 to 99Pa
Pressure resolution: 0.1Pa
Temperature resolution: 0.1 ° C
Touch screen size: 10" / 12" touch screen or industrial tablet
In-cabin purification level: Static class A

Model size of machine Size of operation Air lock chamber size description
YT-R1500 1500*750*2100 1500*650*800 NO Single-sided hard cabin turbulence isolator 3 gloves
YT-DR1500A 2100*1100*2100 1500*1000*800 500*600*500 Double-sided hard cabin turbulence isolator 3+3 gloves
YT-R1800 1800*750*2100 1800*650*800 NO Single-sided hard cabin turbulence isolator 4 gloves
YT-DR1800A 2400*1100*2100 1800*1000*800 500*600*500 Double-sided hard cabin turbulence isolator 4+4 gloves

Hard cabin structure consisting of stainless steel + tempered glass;

The ventilation mode is sent to the top row, and the airflow model is engineering turbulence, which greatly reduces the air volume and simplifies the design of the room ventilation system;

The material door is inflated and sealed, with pneumatic locking and working state interlocking function;

Equipped with H14 grade tank sealed high efficiency air filter;

Integrated vaporized hydrogen peroxide sterilization system and YT-601A, YT-608A type aseptic detection system;

Siemens PCL+ touch screen automatic control;

Siemens Touch Screen Negative Pressure Isolator Log6 For Pharmaceutical Industry

Siemens Touch Screen Negative Pressure Isolator Log6 For Pharmaceutical Industry

Siemens Touch Screen Negative Pressure Isolator Log6 For Pharmaceutical Industry

  • Sterile isolator features

The advantages of sterile isolators compared to traditional clean technology:

1. Automatic gas sterilization saves time and effort, uniform gas distribution, good effect and easy verification.

2, completely isolated from the outside world, only through HEPA gas exchange and constant cabin pressure, to prevent external pollution.

3, double door express delivery system, to ensure delivery in a sterile environment, a high degree of sterility assurance.

4. The umbrella coefficient is high, the running noise is low, and the protection efficiency for operators is very good.

5. The risk of aseptic environmental pollution caused by misuse is very small.

6. The operating energy consumption is lower than that of the traditional clean room.

7, small footprint, does not affect other equipment, and can be flexibly designed according to customer requirements.

Send your message to this supplier
Send Now

Siemens Touch Screen Negative Pressure Isolator Log6 For Pharmaceutical Industry

Ask Latest Price
Brand Name :
WINTEAM
Model Number :
YT-SXXXX
Certification :
ISO9001
Place of Origin :
CHINA
MOQ :
1 set
Price :
Negotiable
Contact Supplier
Siemens Touch Screen Negative Pressure Isolator Log6 For Pharmaceutical Industry
Siemens Touch Screen Negative Pressure Isolator Log6 For Pharmaceutical Industry
Siemens Touch Screen Negative Pressure Isolator Log6 For Pharmaceutical Industry

Hangzhou Winteam Scientific Instruments Co., Ltd.

Active Member
7 Years
hangzhou
Since 2010
Business Type :
Manufacturer, Importer, Exporter
Total Annual :
20,000,000-30,000,000
Employee Number :
150~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement