bioburden testing procedure bioburden testing usp usp microbiology chapters
Mini-size design reduces occupying space of super-clean control console and airflow interference.
Waterproof design of equipment body is used to avoid liquid entering into interior of apparatus.
Concise & modern interface is easy to clean.
Knob with unlimited speed adjustment has memory function of rotating speed.
Mirror-polished treatment on stainless steel equipment box is easy to clean and
Panel type YT-601A/YT-601B for sterility inspection isolation system installation
The ultra-small design reduces the space and airflow interference of the ultra-clean console.
The waterproof design of the fuselage prevents liquid from penetrating into the instrument.
The interface is simple and modern, easy to clean;
Knob stepless speed regulation, with speed memory function;
Stainless steel case mirror finish for easy cleaning and disinfection
New pump head: eccentric tensioning method, easy and quick to operate.
The transmission system uses a low-speed power to drive the motor directly, which reduces the
Introduction
The YT-601 collection instrument is a device used in conjunction with the disposable collection culture incubator. The sample is positively filtered and cultured in the incubator by the directional peristaltic pressure of the collection instrument to test the test sample. Whether it contains bacteria.
Features
Applications
Installation
Unpacking and inspection
Open the box, remove the kit, the instrument and the spare parts and spare parts, and carefully check the contents of the box according to the packing list.
Power connection
Place the instrument on a stable workbench, plug the power cord into the power supply slot on the back of the instrument, and plug the other end into the power supply in the room.
(Note that the power supply voltage and frequency must match the instrument)
Installation method
Place the instrument on a stable operation table, install each accessory as shown in the structure diagram, and insert the power cord plug into the power supply that matches the instrument. After booting, see if it can run normally and effectively. Insert the foot switch cable connector into the socket that does not correspond to the bacteria collection instrument. If you need to remove it, disconnect the power supply and unplug it.
Name | sterility test pump |
Working power supply: | AC220V/50Hz |
Power: | 200W |
Peristaltic pump speed: | 15 ~ 240rpm |
Runner: | 3 wheels |
Height (with bottle holder): | 39cm |
Dimensions: | 34*40*17cm |
Weight: | 17Kg |