Item | Contents | Criteria | |
1 | Model | BEST-#### | 13S-30A/25A working current |
2 | Voltage | Charging voltage | 54.6V |
3 | Current | Maximal continuous charging current | 10A/25A |
Maximal continuous discharging current | 30A/25A | ||
Current consumption | ≤20μA | ||
4 | Overcharge Protection | Over charge detection voltage | 4.2V~4.35V(Adjustable) |
Over charge detection delay time | 0.5S~2S | ||
Over charge release voltage | 4.0V~4.2V(Adjustable) | ||
5 | Over Discharge Protection | Over discharge detection voltage | 2.3V~3.0V(Adjustable) |
Over discharge detection delay time | 50~200mS | ||
Over discharge release voltage | 2.3V~3.0V(Adjustable) | ||
6 | Over Current Protection | Over current detection voltage | 0.1V~0.2V(Adjustable) |
Over current detection current | Adjustable | ||
Detection delay time | 5~20mS | ||
Release condition | Cut load,automatically recover | ||
7 | Short Circuit Protection | Detection condition | Exterior shot circuit |
Detection delay time | 200~500uS | ||
Release condition | Cut load,automatically recover | ||
8 | Balance/Equilibrium | Balance voltage for single cell | 4.20V±0.025V |
Balance current for single cell | 84mA±10mA | ||
9 | Resistance | Inner resistance | ≤20mΩ |
10 | Temperature | Operating temperature range | -40~+85°C |
Storage temperature range | -20~+125°C | ||
11 | Size (L*W*T) | L60mm*W50mm*T25mm |