High Temperature Tunnel Drying Oven Wide Board Heavy Load Chain Conveyor
Heavy load wide board chain +rail conveyor, strong carrying capacity, suitable for heavy load. Compatible conveying width, more flexible, and it can meet the curing needs of a variety of sizes of products. The inlet and outlet can be optional with shifting connection, to improve the use efficiency of the furnace, and meet a variety of complex loading and unloading processes. Full modular design, convenient maintenance, reduce maintenance time and cost. Patented hot air system, more efficient hot air convection conduction, faster heat compensation. New furnace structure design, multi-layer heat insulation, effectively reduce the working environment temperature.
Features:
Application range:
Overall diagram:
01 Monitor
02 Exhaust system
03 Chamber lifting unit
04 Heating module
05 Bottom chamber module
06 Top chamber module
07 Conveyor system
08 Conveyor motor
Options:
1. Pressure charged air cooling
2. Water chiller
1. Multi-channel buffer
2. With shifting connection
The preheating length can be customized.
1. Conveying width can be 500mm, 850mm, or to be customized
2. Multi-channel design
1.Reserve the installation position for the fixture
The guide rail conveying mode can be customized according to the product process requirements.
Product Parameters:
Model | SHR-01K(01-05T 500) | SHR01K(01-05T-850) | Remarks |
Dimension | L3600xW1300xH1685mm | L3600xW1650xH1685mm | |
Weight | Approx.1400kg | Approx.1800kg | |
Power Supply | 3P 5L 380V 50/60Hz | 3P 5L 380V 50/60Hz | |
Control system | PC+PLC | PC+PLC | |
Total Power | Approx.32KW | Approx.32KW | |
Conveying Type | Stainless steel wide board heavy load chain | Stainless steel wide board heavy load chain | |
Conveying width | Max500mm | Max850mm | |
Product height (including fixture) | Max100mm | Max100mm | |
Infeed height | 900±20mm | 900±20mm | |
Conveying Speed | 100-500mm/min | 100-500mm/min | |
Speed control mode | Closed Ioop stepless speed regulation by inverter | Closed Ioop stepless speed regulation by inverter | |
Conveying direction | L-R(Option:R-L) | L-R(Option:R-L) | |
Temperature control mode | PID | PID | |
Temperature range | Room temp~200℃ | Room temp~200℃ | |
Heating system | Heating on the channel | Heating on the channel | |
Heating zones | 5 heating zones | 5 heating zones | |
Heating zone length | 3000mm | 3000mm | |
Cooling zone length | N/A | 无NA | Option |
Warming up time | Approx.15min | Approx.15min | Set temp 150℃ |
Running power | Approx.6KW | Approx.7kW | |
Temperature value display accuracy | 1℃ | 1℃ | |
Abnormal alarm | Three-color signal light+ human-machine interface alarm | Three-color signal light+ human-machine interface alarm | |
Exhaust requirement | 2-Φ150 air outlet,the exhaust air volume of a single air outlet is about 15m³/min | 2-Φ150 air outlet,the exhaust air volume of a single air outlet is about 15m³/min | |
Parameter storage | Process Data and status storage | Process Data and status storage | |
Power cut protection | Equipped with UPS | Equipped with UPS | |
Air source | N/A | N/A | |
1.Option:The front end and rear end of the machine can be extended, and the outer side of the protruding of the upper furnace is300mm(the length of the whole machine will be lengthened 600mm). 2.Note:According to production capacity requirements,the recommended heating zone number is: 4 heating zones,5 heating zones,8 heating zones,9 heating zones,10 heating zones,12 heating zones,which can be customized. |
Notices:
1.Power requirements:
①Three phase five wire: voltage 380V, frequency 50/60HZ;
②The wire diameter requirement is 16mm² or more, with a leakage protection switch of 125A and a leakage capacity of 150-200mA.
2.The ground is required to withstand a pressure of 1000kg/m².
3.External ventilation requirements: Duct specification 2-Ø150mm; Two exhaust ports, with a single exhaust port having an exhaust volume of approximately 15M³/min.