UXT Series Reflow Machine Equipment Low Energy Consumption
Reflow soldering equipment is used to heat the PCB after component placement at high temperatures, melting the solder paste on both sides of the component and bonding it to the circuit board, thus completing the soldering process. The application scope of reflow soldering is very wide, covering almost all production and manufacturing fields of electronic products, such as consumer electronics, lighting, automotive electronics, communication equipment, industrial control, aerospace, energy industry, etc.
Features:
Overall diagram:
Heating module design is easy for maintenance and cleaning. Front and rear reflow design could insulate the heating effect between heating zones in order to achieve the accuracy temperature and longer life-time of hot-air-flow motors. Also by the frequent control of motors, the speed of air flow could be adjusted. | ![]() |
Manual + electric width adjustment structure design, equipped with emergency manual transmission structure in case of PCB burned when power off. | ![]() |
Special adjustable width and transmission design can Ensure stable and reliable PCB transmission by anti-jammed chain. | ![]() |
High stability control system, powerful function. | ![]() |
Product Parameters:
Model No | UTX-810/UTX-810N | UTX-812/UTX-812N | UTX-810/UTX-810N Dual tracks | UTX-812/UTX-812N Dual tracks |
Heating system | ||||
Heating zone structure | 10 heating zones, 20 heating modules | 12 heating zones, 24 heating modules | 10 heating zones, 20 heating modules | 12 heating zones, 24 heating modules |
Heating zone length | 3670mm | 4390mm | 3670mm | 4750mm |
Warming up time | 25min | 25min | 25min | 25min |
Outlet diameter, Displacement | 2-Ø145,Exhaust demand 10m³/min x2 | |||
Cooling system | ||||
Cooling type | Three cooling zones: forced water cooling | |||
Cooling zone length | 1250mm | |||
Power of the chiller | 5P Water chiller | |||
Conveyor system | ||||
PCB Width | Min50mm-max400mm (optional with max510mm) | Adjustable width for dual track min50mm-max250mm Adjustable width for single track min50mm-max450mm | ||
Conveyor Direction | L→R,R→L | |||
Conveyor Height | 900±20mm | 900±20mm | ||
Fixed Rail Side | Front rail Fixed(Option: Rear Rail Fixed) | The front and rear guide rails are fixed, and the middle two guide rails are movable | ||
Conveyor Type | Chain + mesh belt with synchronous transmission | |||
Component Height | Top side clearance 30mm,bottom side clearance25mm | |||
Conveyor Speed | 300mm-2000mm/min | |||
Guide rail structure | Dust free special hardening guide rail | |||
Control system | ||||
Power | AC3Ø 5W 380V 50/60HZ | |||
Total Power | 96KW | 117KW | 96KW | 117KW |
Start Up Power | 38KW | 42KW | 38KW | 42KW |
Normal running | 10KW | 12KW | 11KW | 13KW |
Temp Control Range | Room temperature to 320℃ | |||
Control type | PC+PLC Control system | |||
Temp Control Accuracy | ±1℃ | ±1℃ | ||
PCB Temp Deviation | ±1℃ | ±2℃ | ||
Data Storage | Process Data and status storage | |||
Power-off Protection | Equipped UPS | |||
Operation Interface | Windows Chinese simplified, English online free switching | |||
N2 area | Full nitrogen filling(The model with "N" refers to the nitrogen model) | |||
MES communication protocol | Standard | |||
Computer | Commercial PC | |||
General | ||||
Dimension(LxWxH) | 6400x1580x1650mm | 7120x1580x1650mm | 6400*1710*1650mm | 7120*1710*1650mm |
Weight | 2500-2700kg | 3000-3200kg | 2900-3100kg | 3500-3700kg |
Flux recovery system | Standard | |||
Machine Color | Bright wrinkled white |
Notices:
1.Power requirements:
①Three phase five wire: voltage 380V, frequency 50/60HZ;
②Wire diameter above 25mm², leakage protection switch 160A, leakage protection switch leakage capacity 150-200mA.
2.The ground is required to withstand a pressure of 1000kg/m².
3.External ventilation requirements: air duct Ø145mm, ventilation volume 15-20M³/min.