SST Series Compact Durable Reflow Machine High-Volume
Reflow soldering equipment is used to heat the PCB after component placement at high temperatures, melting the solder paste on both sides of the component and bonding it to the circuit board, thus completing the soldering process. The application scope of reflow soldering is very wide, covering almost all production and manufacturing fields of electronic products, such as consumer electronics, lighting, automotive electronics, communication equipment, industrial control, aerospace, energy industry, etc.
Features:
Overall diagram:
Product Parameters:
Model No | SST-08A/S5T-08N | S5T-10A/SST-10N | SST-12A/SST-12N | SST-08DA/S5T-08DN | S5T-10DA/SST-10DN | SST-12DA/SST-12DN |
Heating System | ||||||
Heating Zone | 8 heating zones, | 10 heating zones, | 12 heating zones, | 8 heating zones, | 10 heating zones, | 12 heating zones, |
Heating Length | 3120mm | 3870mm | 4635mm | 3120mm | 3870mm | 4635mm |
Cooling Type | Three coaling zones: forced air cooling/water coaling | |||||
Outlet Exhaust Demand, Valume | 2-Φ145,Exhaust demand15m³/minx 2 | |||||
Conveyor System | ||||||
Product Width | min50mm-max400mm | min50mm-max270mm(Dual track simultaneous) min50mm-max500mm(Dual track single use) | ||||
Conveying Direction | L→R,R→L | |||||
inlet Height | 900±20mm | |||||
Fixed Rail Side | Front rail Fixed(Option:Rear Rail Fixed) | Front and Rear Rails Fixed,central two rails are movable | ||||
Conveyor Type | Chain+mesh belt synchronous transmission | |||||
Component Height | Clearance based on the rail:above 30mm, below 25mm | |||||
Conveying Speed | 300mm-2000mm/min | |||||
Control System | ||||||
Power Supply | AC3Φ,5W,380V,50/60HZ | |||||
Total Power | 59KW | 73KW | 91KW | 70KW | 89KW | 108KW |
Start up Power | 30KW | 35KW | 40KW | 35KW | 40KW | 45KW |
Running Power | 7.5KW | 9.5KW | 11.5KW | 10KW | 11.5KW | 13KW |
Temperature Range | Room temp to 320℃ | |||||
Control Type | PC+PLC Control System | |||||
Rail Width Adjusting Mode | Electric+Manual | |||||
Temp Control accuracy | ±1℃ | |||||
PCB Temp Deviation | ±1℃ | ±2℃ | ||||
Data Storage | Process Data and status storage | |||||
Power Outage Protection | Equipped with UPS | |||||
Operation Interface | Windows Chinese simplified,English online free switching | |||||
General | ||||||
Dimension(L×W×H) | 5550*1450*1620 | 6300*1450*1620 | 7065*1450*1620 | 5550*1735*1620 | 6300*1735*1620 | 7065*1735*1620 |
Weight | 2200-2400kg | 2600-2800kg | 3000-3200kg | 2700-2900kg | 3000-3200kg | 3300-3500kg |
Color | Bright wrinkled white |
Notices:
1.Power requirements:
①Three phase five wire: voltage 380V, frequency 50/60HZ
②Wire diameter above 25mm², leakage protection switch 160A, leakage protection switch leakage capacity 150-200mA
2.The ground is required to withstand a pressure of 1000kg/m²
3.External ventilation requirements: air duct Ø145mm, ventilation volume 15-20M³/min.