0.5n/S Indoor 10 Degree Moving Walkway For Public Transportation
MODEL: Moving Walkway
Applicable Site: Shopping mall, supermarket
Standard: EN115-1:2008+A1:2010 GB16899
Energy Saving&Environmental Protection: frequency conversion control technology
Description:
- Indoor
- Speed <=0.5m/s
- Use section length: L<=43.47m
- Step width:800mm, and 1000mm
- Angle: 10°,11°, 12°
Distance of Support | ||||||
Inclination | Rising height (мм) | Intermediate support | La | Lb | Lc | |
R3 | R4 | |||||
10° | 1500-3200 | ------ | ------ | ------ | ------ | ------ |
3200-4800 | 1 | ------ | L/2 | L/2 | ------ | |
4800-6000 | 1 | 1 | L/3 | L/3 | L/3 | |
11° | ≤4200 | ------ | ------ | ------ | ------ | ------ |
4200-6000 | 1 | ------ | L/2 | L/2 | ------ | |
≤6000 | 1 | 1 | L/3 | L/3 | L/3 | |
12° | ≤4200 | ------ | ------ | ------ | ------ | ------ |
4200-6000 | 1 | ------ | L/2 | L/2 | ------ | |
≤6000 | 1 | 1 | L/3 | L/3 | L/3 |
Motor power (Kw) | ||
Step Width (mm) | Rising height (мм) | Power |
1000 | 1200-3000 | 5.5 |
3000-4500 | 8 | |
4500-6000 | 11 | |
800 | 1200-3800 | 5.5 |
3800-5500 | 8 | |
5500-6000 | 11 |
Reaction of support | |||
Reaction Supports | None intermediate Supports | One intermediate support | Two intermediate Supports |
R1(KN) | L x q + M | La x q + M | La x q + M |
R2(KN) | L x q + N | Lb x q + N | Lb x q + N |
R3(KN) | ---------------- | (La + Lb) x 1.3 x q | (La + Lc) x 1.3 x q |
R4(KN) | ---------------- | ---------------- | (Lb + Lc) x 1.3 x q |
Dimensions (MM) | |||
A | Width of step | 800 | 1000 |
C | Width of travolator | 1400 | 1600 |
B | Width of handrail | 1038 | 1238 |
D | Width of pit | 1460 | 1660 |
FAQ
1. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
2. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
3. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
4. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.