1000kg/0.5m/S Freight Elevator With Big Cabin & Telescopic Door Opening
The firm and durable cabin
Highly accurate leveling
High strength plate ensures the firm and durable cabin. In addition, it specially designs crash barrier to implement multi-protection to the cabin.
Leveling accuracy can be controlled within millimeter-sized range.
Energy-saving
Frequency conversion freight elevator applies VVVF and speed regulative technology. It thus greatly reduces the elevators running power consumption and power supply capacity. Compared with the traditional AC-2 speed type elevator, it can save 30%-50% energy.
Large door width
Adopt multi-panel cabin doors to reach the maximum door opening width, making it easy for handing large goods.
MACHINE ROOMLESS FREIGHT ELEVATOR
More released big spaces
Elevators compact structural design can save space. It accords with attractive requirements from various buildings. Application of gearless traction machine saves energy and reduces consumption. It coincides with future elevator development trend.
Load(kg) | Speed(m/s) | Cabin size | Door size | Hoistway | Pit depth(mm) | Overhead height(mm) | Opening mode |
WxDxH(mm) | WxD(mm) | WxD(mm) | |||||
1000 | 0.5 | 1600x1500x2200 | 1300x2100 | 2600x2100 | 1700 | 4200 | 2 panels telescopic opening |
1600 | 0.5 | 1600x2200x2200 | 1300x2100 | 3000x2800 | 1700 | 4500 | |
2000 | 0.5 | 1900x2200x2200 | 1500x2100 | 3300x2800 | 1700 | 4500 | |
3000 | 0.5 | 2200x2700x2200 | 1800x2100 | 3700x3200 | 1700 | 4800 | 4 panels Center opening |
5000 | 0.5 | 2400x3600x2200 | 2000x2100 | 4100x4100 | 1800 | 5500 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.