Customized Diamane Commercial Elevator Lift Passenger Elevator
1.0m/S Machine Room Passenger Elevator Lift With Deceleration Device
What was the impact of the passenger elevator?
The elevator allowed the skyscraper to reach new heights. Had the elevator not been utilized, the buildings would only be built as tall as a person can feasibly climb up stairs. At first, the poorest of people lives on the highest of floors due to this discomfort.
NO. | Rated capa city (kg/person) | Speed(m/s) | Net size of car | Net door size | Net size hoistway | Pit depth | Overhead height | Machine room size | Opening mode |
1 | 450(6) | 1.0 | 1200*1100*2400 | 800*2100 | 1800*1800 | 1400 | 4200 | 1800*1800*2200 | center opening |
2 | 630(8) | 1.0 | 1400*1200*2400 | 800*2100 | 2000*1850 | 1400 | 4200 | 2000*1850*2200 | |
1.5/1.75 | 1700 | 4500 | |||||||
3 | 800(10) | 1.0 | 1400*1400*2400 | 800*2100 | 2100*2050 | 1400 | 4200 | 2100*2050*2400 | |
1.5/1.75 | 1700 | 4500 | |||||||
2.0 | 2000 | 4800 | |||||||
4 | 1000(13) | 1.0 | 1600*1500*2400 | 900*2100 | 2200*2150 | 1400 | 4200 | 2200*2150*2400 | |
1.5/1.75 | 1700 | 4500 | |||||||
2.0 | 2000 | 4800 | |||||||
2.5 | 2300*2300 | 2500 | 5200 | 2300*2300*2400 | |||||
3.0 | 2800 | 5800 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.