Voltage 5 - 25v Elevator Safety Components Sensor For Speed Measurement
Application & features:
Applied for elevator speed measurement and motion direction control.
High Anti-interference performance.
High stability.
Specification:
Frequency Response | 0~400Hz |
Application Example | DC8V(RL=1kΩ) |
Operating Voltage | DC 5-25V |
Cutoff Current | ≤1mA |
Forward current | ≥4m A |
Return Difference | ≤5% |
Coil Position | Inside |
Repeat accuracy | ≤5% |
Hysteresis | Less than 10% of detecting distance |
Outline Dimension | M12X1,L=31~35mm |
Detecting Distance | 2mm |
Standard Induction Material | Brass with nickel plated |
Protection Rating | IP66 |
Operating Temperature | -25℃~+70℃ |
Shock | 500m/s²,3 times per axial(XY) |
Vibration | 10-55Hz,Amplitude 1mm, half an hour per axial(XYZ) |
Electrical Performance:
Wire connection & Mounting Dimensions:
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.