30 Degree Vvvf Control Indoor Escalator For Shopping Mall & Commercial Center
Escalators efficiently move large numbers of people with minimum waiting time. However, they operate constantly regardless of the number of passengers they carry. Therefore, even a small decrease in energy consumption produces substantial savings. An approximate 25% reduction in energy consumption has been achieved by enhancing drive transmission efficiency and reducing friction.
Commercial Escalator
Technical Data
Escalator | Indoor and Outdoor |
Travel Height | H≤24000mm |
Inclined Degree | 30°, 35° |
Speed | 0.45m/s, 0.5m/s |
Flat Step | 2 flat step, 3 flat step |
Step Material | Stainless steel, Aluminum (standard for outdoor) |
Step Width | 600mm, 800mm, 1000mm |
Escalator Width | 1240mm, 1440mm, 1640mm for 35 incline |
Capacity (persons/h) | 6000, 9000 |
Balustrade | Tempered glass (10mm), vertical to truss |
Balustrade height | 900mm, 1000mm (optional) |
Balustrade bracket | Stainless steel |
Handrail | C type, Black (Red, Blue, Gray) |
Handrail drive | Big friction wheel |
Power Supply | Motor Power: 380V±7%, 50Hz , 3 Phase |
Lighting Power: 220V, 50Hz, Single Phase | |
Control system | Std.(Star delta) |
Energy Saving Function | Auto Restart, from stop to high speed |
Photoelectricity VF low speed , speed from low to high | |
VF Restart, speed from stop to low to high | |
Step chain | Roller built-in |
Track radius | 1500/1000mm |
Truss | Squre tube |
Standard | GB16899-2011 CE, EN115-2008(2010A+) |
Contact | 86-158-6847-4159 |
Escalator Construction Sketch
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.