CE EAC Certified Smooth Running Safe Stable Passenger Elevator Price Competitive
Capacity
Passenger elevators' capacities are related to the available floor space. Generally passenger elevators are available in capacities from 1,000 to 6,000 pounds (450–2,700 kg) in 500 lb (230 kg) increments.
Speed
Generally passenger elevators in buildings with eight floors or less are hydraulic or traction, which can reach speeds up to 200 ft/min (1.0 m/s) hydraulic and up to 500 ft/min traction. In buildings up to ten floors, traction and gearless elevators are likely to have speeds up to 500 ft/min (2.5 m/s), and above ten floors, speeds begin at 500 ft/min (2.5 m/s) up to 2000 ft/min (10 m/s).
MAIN SPECIFICATIONS | |
Load Capacity | 450~2700Kg |
Rated Speed | 1.0m/s~10.0m/s |
Cabin Width | 1000~2000mm |
Cabin Depth | 1000~2400mm |
Cabin Height | 2000~2800mm |
Open Width | 700~1200mm |
Open Height | 2000~2400mm |
Door Opening | Center Open/Side Open |
Max. Floor No. | 50 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.