RO desalination unit ro filter unit industrial ro unit
Please Attention
HY FACTORY OFFER YOU :
1: FACTORY DIRECT PRICE.
2: NICE QUALITY.
3: ONLINE PAYMENT.
4: SUPPORT REFUND AFTER YOUR INSTALLED THE PLANT IF THERE ARE ANY PROBLME.
5: AFTER SALES SERVICES 24/7
6. Letters patent
7. ENGINNER CAN BE OVERSEA INSTALLNATION
We have 2 factories +300 workers+ Qualified engineer+ Engineer Overseas service
RO desalination unit ro filter unit industrial ro unit
1. RO unit use automatic control and semi-control .Pretreatment parts can adopt fiber glass or stainless steel material.
2.Ro desalination unit has protected when no power, poor power, larger electrical current, leakage, short circuit.
3.Industrial ro unit is compact, easy installation.
4.Industrial ro unit equipped with manual and auto control based on user needed.
5. RO unit produce as per ISO and SGS standard and main parts accessories have obtained CE certification.
6. All the plants will be commissioning well. Make sure don't have any problem when arrived site.
7.What we provide not only the good products, but also our whole team, the quality, experience, and service.
How RO unit to work
Sea water ro unit use Reverse Osmosis to make water. This is the opposite process of osmosis that plants use. Haiyuan definition of Sea water ro unit and description below:
· Reverse osmosis (RO unit) is a separation process that uses pressure to force a solvent through a membrane that retains the solute on one side and allows the pure solvent to pass to the other side.
· The membranes used for reverse osmosis have a dense barrier layer in the polymer matrix where most separation occurs. In most cases the membrane is designed to allow only water to pass through this dense layer while preventing the passage of solutes (such as salt ions).
· This process requires that a high pressure be exerted on the high concentration side of the membrane, usually 2 to17 bar 30 to 250 psi, for fresh and brackish water, and 40 to 70 bar 600 to 1000 psi, for seawater, which has around 24 bar 350 psi, natural osmotic pressure which must be overcome.
· Although Reverse Osmosis seems like a complex system it is really a simple and straightforward water filtration process. High-pressure (pump driven) reverse osmosis systems have been used for years to desalinate water to convert brackish or sea water to drinking water.
Product details of RO unit
Model | HY-2000LPH | Remark |
Product Capacity | 2m3/hr |
|
Power supply | 1PH x 220V, 50Hz |
|
Feed water pump | Q= 2.5m3/h | GRUNDFOS/DENMARK |
Sand filter | Φ400×1520(mm) | FRP |
Activated carbon filter | Φ400×1520(mm) | FRP |
Water softener | Φ400×1520(mm) | FRP (option) |
Micron cartridge filter | Φ159×500(mm) | SUS304 |
1st High pressure pump | Q= 2.5m3/h | GRUNDFOS or CNP |
2nd High pressure pump | Q= 1.25m3/h | GRUNDFOS or CNP |
RO membrane | 4040 | HYDRANAUTICSL or FILMETC |
RO membrane vessel | 4040 x 2, 4 PCS | FRP |
UV sterilizer | 18W | SUS304 (Option) |
Ozone generator | 120W | SUS304 (Option) |
Ro desalination unit
Seawater has high salt content, high hardness, and is corrosive to equipment, and the seasonal changes in water temperature make the reverse osmosis desalination system much more complicated than the conventional brackish water desalination system, and the engineering investment and energy consumption are also much higher. .Therefore, it is extremely important to reduce project investment and energy consumption through careful process design and reasonable equipment configuration, thereby reducing the unit water cost and ensuring the stable operation of the system.
WATER QUALITY STANDARD:
In accordance with national living drinking water standard
World Health Organization living instant-drinking water standard
Major uses
Pure water,mineralized water,natural water,mineral water;
Liquor blending water production,beer production water
Food,beverage production using pure water
Hotels,buildings,drinking water straight community livelihood.
Quality Assurance
(1).Pre-shipment testing and commissioning and machine inspection
(2).Non-destructive testing of welds according to specifications before delivery
(3).Warranty:2-3year
Why we make you choose our RO desalination unit ro filter unit industrial ro unit?
1. We can provide oversea service to site installation.
2. OEM&ODM available.
3. The punctual delivery of goods, quality and quantity guaranteed.
4.We have a professional team to provide customers with pre-sales, in-sales and after-sales services.
5.We can provide technical support via phone/email/instant communication tools, or remote video.
6.We have equipment installation/debugging/maintenance, and provide detailed video tutorials (including paper and electronic documents).
7.Portable seawater desalination RO machine packing: Plywood case packing for exporting.
8.We have shipping forwarder to deliver all over the world, customers also can use your own shipping agents.
Real comments from our client, Trust you will like our products.
RO unit Buying Guides
To find the most appropriate ro desalination unit for your use, please have the following information ready
· Product water flow rate ( m3/hr, m3/day, Liter/hr,GPM,GPD etc.)
·· Product water purpose(drinking, irrigation, industry process or others)
· Feed Water TDS (Total dissolved solids). Is it from Borehole/salt/brackish/lake water
· Iron
· Manganese
· TSS(Total Suspended Solid)
· SDI(Silting Density Index)< 3
· Water must be free from oils and grease
· Chlorine must be removed
· Power (110/220/380V/415V/460V, 50 or 60 Hz) 3 phase.
· It is necessary to make water analysis reprot for borehole water,lake water, seawater.
· If soure water is tap water no need end to us TDS or water analysis report.
Send your Inquiry Details in the Below, Click "Send" Now!