Lithium Battery Primary C Size 3.6V ER26650 9AH for Alarm or Security Equipment
Item | Measuring Procedure | Standard |
1.Appearance | Visual check | Clean, unscratched and clearly labeled |
2.Dimenaions | Measured by calipers with precision of 0.02mm | Max φ26.2×65.0mm |
3.Weight | Weighed by balance with precision of 0.1g | Max 55g |
4.Open-circuit voltage | Measure by volt-meter with precision of 0.01V | ≥3.65V |
5.Operating voltage | Measure by volt-meter with precision of 0.01V, connecting an impedance of 330Ωin series, Reaching the target voltage in 5 seconds. | ≥3.45V |
6.Nominal discharge | 330Ω,20±2℃, Constant discharge to 2.0V. | ≥9000mAh |
7.Rapid discharge | 62Ω,20±2℃, Constant discharge to 2.0V. | ≥8800mAh |
Packing for 3.6V1/2AA Li-soci2 Lithium Battery ER14250S 900mAh for Medical Device
the battery pack with blue PVC jacket
specially sponge pallet fix each battery
standard 7 level strong paper carton
Characteristic Curves
Unless other request s, all tests are carried out in ambient temperature 20±5℃.
Tests should be made within 45 days after receipt of the batteries.
We keep stock for this model continue
So we can delivery the cargo within3-5 days after the buyer arrange the payment
30 days for OEM order