UTP Cat 5e Cable, Cat 5e Network Cable, Cat 5e Ethernet Cable Application
It can be applied in horizontal cabling, as the portion of the building digital security system that extends from the work area (cameras, etc.) telecommunications outlet to the patch panels in the distribution room.
As a crucial part of digital security system, horizontal cabling calls for higher reliability and compatibility.
TC's UTP-15 series, indoor security unshielded cabling system has test frequency up to 100MHZ.
In the meantime, it supports 100 Base-T/1G Base-T applications and long range POE/POE+.
Product Features
TC's 24 AWG, 4-pair, unshielded indoor security cable has a smaller diameter, optimized to greatly enhance technical indicators, including Attenuation and NEXT. It meets the requirements of Q TC J1.1-2018 standards by Shanghai Tiancheng Communication Technology Corp. and "Security Cable Standards" (provisionally named, still in the making) by the Ministry of Public Security.
The cable ensures high-speed and stable cable transmission, mainly used for video surveillance, access control, building intercom in building security system.
Application Standards
GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2
Technical Details
Transmission Performance | Cat.5E | TC | |||||
Frequency (MHz) | 4 | 10 | 20 | 31.25 | 62.5 | 100 | 150 |
IL Attenuation (dB/100M) | 3.8 | 6.1 | 11 | 15.8 | 17.9 | 20 | 23.6 |
Near End Crosstalk Attenuation (NEXT, dB) | 80 | 77 | 61.1 | 58.2 | 62 | 66.3 | 47.7 |
NEXT Power and PS NEXT (dB) | 68.8 | 60.3 | 52.9 | 50.5 | 46.9 | 41.9 | 40.1 |
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) | 82.2 | 72.7 | 76.3 | 75.7 | 69.6 | 71.3 | 68.7 |
ACR-F Power and PS ACR-F (dB) | 68.7 | 64.2 | 69.5 | 69.2 | 66.5 | 61 | 56.3 |
Return Loss (RL, dB) | 46 | 66.6 | 37.5 | 41.5 | 36.9 | 32.2 | 28.9 |
Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.
Physical Specifications | |
Conductor Size (nominal value) | 4×2×0.48 (AWG24) |
Outer Diameter of Cable (nominal value) | 5.0mm |
Weight (305m, with package, nominal value) | 9kg |
Electrical Properties | |
DC resistance (20℃ ) | 100Ω/km |
Earth Capacity | ≦ 5.6 nF/100m (@1kHz) |
100MHz Characteristic Impedance | 100Ω±15Ω |
Transverse Conversion Loss (TCL) | ≥ 50dB-10×lgf (4-100MHz) |
Delay Skew | None required |
NVP | 69% |
Power Over Ethernet (POE) | Enhanced Power Over Ethernet under IEEE 802.3at |
Mechanical Properties | |
Minimum Bend Radius (dynamic) | 20mm |
Minimum Bend Radius (static) | 40mm |
Maximum Installation Tension | 100N |
Anti-Extrusion Capacity | 1000N/10cm |
Anti-Shock Capacity | ≥ 10 times |
Installation Temperature Range | -0℃ ~+40℃ |
Working Temperature Range | -20℃ ~+75℃ |
Flammability (PVC) | |
PVC Flame Resistance | GB/T 18380.12 (IEC 60332-1-2) |
Fire Rating CM/CMR | UL 1581 |
Flammability (LSZH) | |
Flame Resistance (of single wire) | GB/T 18380.12 (IEC 60332-1-2) |
Smoke Density | GB/T 17651 (IEC 61034-1/-2) |
Hazardous Halogen Gas | GB/T 17650.1/.2 (IEC 60754-1/-2) |