Specifications
Brand Name :
TC
Model Number :
SFTP-11-6A-4P-V1
Certification :
UL, RoSH, REACH, CE
Place of Origin :
China
MOQ :
50 Boxes
Price :
Negotiable
Payment Terms :
Western Union, T/T, L/C, MoneyGram
Packaging Details :
Seaworthy Packing
Type :
Cat 6A SF/UTP
Conductor Material :
99.99% BC
Conductor OD :
23 AWG
Drain Wire :
No
Cross Spline :
PE
Insulation :
HDPE
PVC Flame Resistance :
GB/T 18380.12 (IEC 60332-1-2)
Length :
305 m/box
Description

Cat 6A Cable, CAT 6A Network Cable, CAT6A Ethernet Cable, SFTP CAT6A​ Application


It can be applied in horizontal cabling, as the portion of a telecommunications cabling system that extends from the work area telecommunications outlet to the patch panels in the distribution room, and in residential cabling that extends from the user telecommunications outlet to the patch panels.

TC's SFTP-11 series, indoor Cat 6A dual shielded cabling system has test frequency up to 600MHZ, higher than other Cat 6A cables with industry standard of 500MHz.

In the meantime, it supports 10G Base-T applications and Power Over Ethernet (POE/POE+).

Product Features


TC's Cat 6A, 23 AWG, 4-pair, SF/UTP dual shielded indoor cable adopts cross-type spline, copper mesh braid and overall aluminum foil shield, optimized to greatly enhance technical indicators, including Attenuation, NEXT, and ANEXT, which exceed the parameters specified in GB/T 18015.5 (IEC 61156-5) standards.

It is especially useful in some harsh electromagnetic environments where high-speed and stable cable transmission is required.

At the same time, it acts on the requirements for high transmission in data center, and structured structured cabling in new buildings.

Application Standards


GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2

SFTP Cat 6A Cable CAT 6A Network Cable 23 AWG Bare Copper PVC Jacket

Technical Details

Transmission Performance Cat.6A TC
Frequency (MHz) 4 31.25 62.5 100 300 500 600
IL Attenuation (dB/100M) 3.5 10.1 14.4 18.2 32 42.4 49.4
Near End Crosstalk Attenuation (NEXT, dB) 92.1 98.7 89 93.1 77.4 73.6 75.6
NEXT Power and PS NEXT (dB) 90.4 89.1 85.4 88.6 73.9 69.8 70.2
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) 95.8 91.5 87 84.1 76.4 71.6 72.6
ACR-F Power and PS ACR-F (dB) 91.4 88.1 85.4 86.3 76.9 69.1 67.9
Return Loss (RL, dB) 40.9 41.3 37.9 35 30.7 22.7 19.7


Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.

Physical Specifications
Conductor Size (nominal value)
4×2×0.57 (AWG23)
Outer Diameter of Cable (nominal
value)
8.2mm
Weight (305m, with package,
nominal value)
21kg

Electrical Properties
DC resistance (20℃ )
93.8Ω/km
Earth Capacity ≦ 5.6 nF/100m (@1kHz)
100MHz Characteristic Impedance
100Ω±20Ω
Transverse Conversion Loss (TCL)
≥ 55dB-20×lgf (100-2000MHz)
Delay Skew 25ns/100m
NVP
69%
Power Over Ethernet (POE) Enhanced Power Over Ethernet under IEEE 802.3at

Mechanical Properties
Minimum Bend Radius (dynamic)
33mm
Minimum Bend Radius (static)
66mm
Maximum Installation Tension
100N
Anti-Extrusion Capacity 1000N/10cm
Anti-Shock Capacity ≥ 10 times
Installation Temperature Range -0℃ ~+40℃
Working Temperature Range -20℃ ~+75℃

Flammability (PVC)
PVC Flame Resistance GB/T 18380.12 (IEC 60332-1-2)
Fire Rating CM UL 1581/ UL 1666

Flammability (LSZH)
Flame Resistance (of single wire) GB/T 18380.12 (IEC 60332-1-2)
Flame Resistance (of bunched wires) GB/T 18380.35 (IEC 60332-3-24)
Smoke Density GB/T 17651 (IEC 61034-1/-2)
Hazardous Halogen Gas GB/T 17650.1/.2 (IEC 60754-1/-2)
Send your message to this supplier
Send Now

SFTP Cat 6A Cable CAT 6A Network Cable 23 AWG Bare Copper PVC Jacket

Ask Latest Price
Brand Name :
TC
Model Number :
SFTP-11-6A-4P-V1
Certification :
UL, RoSH, REACH, CE
Place of Origin :
China
MOQ :
50 Boxes
Price :
Negotiable
Contact Supplier
SFTP Cat 6A Cable CAT 6A Network Cable 23 AWG Bare Copper PVC Jacket

TC Smart Systems Group

Verified Supplier
5 Years
guangxi, shanghai
Since 1988
Business Type :
Manufacturer
Total Annual :
250-300 Million
Employee Number :
1500~2000
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement