Specifications
Brand Name :
TC
Model Number :
CAG61220
Place of Origin :
China
Material :
Cold rolled steel, Tempered Glass
Surface Treatment :
Electrostatic Powder Sprayed in Surface
Electrostatic Protection :
In accordance with GB50611
Power Supply and Distribution :
In accordance with GB50052, GB50054
Lightning Protection :
In accordance with GB50343
Air Conditioning :
In accordance with GB50019, GB50243
Fire Extinction :
In accordance with GB50263
Standard :
GB/T 18233 (ISO/IEC 11801); GB 50311; GB50174; TIA/EIA568-C.2
Description

Data Center Containment, Data Center Cooling System Application

Data center cabinets are facing a lot of challenges: higher heat density, greater electric energy consumption, lack of space, and cabinet layout not keeping up with the needs of business growth.

There have always been increasing requirements for cooling, though air conditioners are frequently replaced and added.

However, there still exists the partial heat island problem, that is, the direct mix of cold and hot air resulting in a huge waste of cooling capacity.

The equipment on top of the cabinet cannot acquire enough cooling capacity as needed, so the overall PUE value remains high.

The cold/hot aisle containment system separates the cold inlet air and the hot exhaust air. The cold air is pushed under the raised floor and through the closed cold aisle. As the cold air concentrates in front of the cabinet and cools the equipment, it is heated and eventually dissipated into the hot aisle. The hot exhaust air is then routed back to the outlet of the air conditioner.

Product Features

Thanks to the hot aisle and cold aisle, the cabinets are no longer placed in the same direction.

The fronts of the racks face each other, which fits for the front-to-back heat dissipation of most IT equipment. In doing this, an unnecessary mix of cold and hot air is thus avoided for improved cooling efficiency.

Application Standards

GB/T 18233 (ISO/IEC 11801); GB 50311; GB50174; TIA/EIA568-C.2

Aisle Components

Functional Skylight

  • Installed in front and rear of the cold aisle, space reserved for hygrometer and thermometer, smoke alarm, surveillance cameras, and other equipment

Fire Fighting Linkage Retractable Skylight

  • Installed in the middle of the cold aisle, in a dual flip structure for a decrease in space utilization on top

Fully Transparent Fixed Skylight

  • Installed in the middle of the aisle, with a huge scale of tempered glass, for better light penetrability inside the aisle

Electric Sliding Door

  • Installed in front and rear of the aisle, with door access, anti-pinch, exit button, alarm, and the screen

Double Flush Door

  • Install in front and rear of the aisle, with door access, exit button, alarm, and automatically closed door

Double Manual Sliding Door

  • Installed in front and rear of the aisle, with door access, alarm, and automatically closed door


Technical Details

Specifications
Range of Altitude 0-2000 m
Operating Temperature Range -15℃to 45℃
Operating Humidity Range 0 to 85%
Electrostatic Protection Following GB50611
Power Supply and Distribution Following GB50052, GB50054
Lightning Protection Following GB50343
Air Conditioning Following GB50019, GB50243
Fire Extinction Following GB50263
19-inch Cabinet In accordance with GB3047.2, IEC297-2, DIN41491 PART1, DIN41494 PART7, ANSI/EIARS-310-D; compatible with ETSI

Send your message to this supplier
Send Now

Data Center Containment Cold Aisle Containment

Ask Latest Price
Brand Name :
TC
Model Number :
CAG61220
Place of Origin :
China
Material :
Cold rolled steel, Tempered Glass
Surface Treatment :
Electrostatic Powder Sprayed in Surface
Electrostatic Protection :
In accordance with GB50611
Contact Supplier
Data Center Containment Cold Aisle Containment

TC Smart Systems Group

Verified Supplier
5 Years
guangxi, shanghai
Since 1988
Business Type :
Manufacturer
Total Annual :
250-300 Million
Employee Number :
1500~2000
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement