Mean Well LRS Series 150W Single Switching Power Supply LRS-150 LRS-150-24 LRS-150-12 24V 6.5A 12V6.2A LRS-150-12
Mean Well LRS Series 150W Single Switching Power Supply LRS-150 LRS-150-24 LRS-150-12 24V 6.5A 12V6.2A LRS-150-12
Applications :
Description:
LRS-150 series is a 150W single output enclosed type power supply with 30mm of low profile deign,Adopting the full range 85-264Vac input, the entire series provides an output voltage line of 12V.15V,24V,36V and 48V
In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-150 that the whole series operates from -30°through 70 °under air convection without a fan.
Delivering an extremely low no load power consumption ( less than 0.3W), it allows the end system to easily meet the worldwide energy requirement .
Technical
MODEL | LRS-150-12 | LRS-150-15 | LRS-150-24 | LRS-150-36 | LRS-150-48 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 12.5A | 10A | 6.5A | 4.3A | 3.3A | |
CURRENT RANGE | 0 ~ 12.5A | 0 ~ 10A | 0 ~ 6.5A | 0 ~ 4.3A | 0 ~ 3.3A | |
RATED POWER | 150W | 150W | 156W | 154.8W | 158.4W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load | |||||
HOLD UP TIME (Typ.) | 40ms/230VAC 35ms/115VAC at full load | |||||
INPUT | VOLTAGE RANGE | 85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC) | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
EFFICIENCY (Typ.) | 87.5% | 88.5% | 89% | 89% | 90% | |
AC CURRENT (Typ.) | 3A/115VAC 1.7A/230VAC | |||||
INRUSH CURRENT (Typ.) | COLD STAR 60A/230VAC | |||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||
PROTECTION | OVER LOAD | 110 ~ 140% rated output power | ||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | 13.8 ~ 16.2V | 18.75 ~ 21.75V | 28.8 ~ 33.6V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||
OVER VOLTAGE CATEGORY | Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters | |||||
SAFETY & EMC (Note 7) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1, BSMI CNS14336-1, EAC TP TC 004,KC K60950-1(for LRS-150-12 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005, AS/NZS 62368.1(by CB) approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤75% Load), BS EN/EN61000-3-3,GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only) | |||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only) | |||||
OTHERS | MTBF | 2707.7K hrs min. Telcordia SR-332 (Bellcore) ; 558.2Khrs min. MIL-HDBK-217F (25℃) | ||||
DIMENSION | 159*97*30mm (L*W*H) | |||||
PACKING | 0.48Kg ; 30pcs/15.4Kg/0.75CUFT |
Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.
7 What about the quality ?
A:100% original with new package. we will test each item before posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.