Eltek rectiverter Indoor system Scalable system 18-54KVA 220Vdc AC backup power for 400 VAC Or 230Vac (CIEJ3643.4xxx )
Eltek rectiverter Indoor system Scalable system 18-54KVA 220Vdc AC backup power for 400 VAC Or 230Vac (CIEJ3643.4xxx )
The scalable Rectiverter indoor system provides AC backup power for
400 VAC 3-phase or 230 VAC 1-phase loads, and 220 VDC power for battery
charging and optional DC loads. The flexible DC output can be set to
recharge large battery backup with protection time up to 10 hours.
In combination with the optional B-input (dual AC input) eliminates the
need for a traditional ATS (Automatic Transfer Switch). Where the switch from A to B input
, is a seamless operation with no
interruption on the AC load
.
In combination with the optional B-input (dual AC input) eliminates the need for a traditional ATS (Automatic Transfer Switch).Where the switch from A to B input, is a seamless operation with no interruption on the AC load.
When configured with dual AC input for use as an AC UPS, it classifies as - VFI SS 111 according to EN 62040-3
l 400 VAC 3 phase (Y) input
l 400 VAC 3 phase (Y) output
l 220VDC input/output
l Max 54 kVA / 43,2 kW AC output
l Max 43,2 kW DC output
l Protected bulk AC output
l A+B option (dual AC input)
l Manual bypass option
l Up to 4 battery strings
l Built in transfer technology
l 150% overload capability, 15S
l 600% quick trip current 20 ms
l Hot pluggable
l Smartpack2 controller
l Operates in paralell with Flatpack2 rectifiers
l Global compliance
l Patented HE technology
Parameters :
Models / ordering information | 54 kVA + 48 kW A-Input | 54 kVA + 48 kW B-Input | |
Product family | CIEJ3643.4xxx | CIEJ3643.4 xxx | |
AC OUTPUT DATA | |||
Voltage (default) / (adjustable range)1) | 400 VAC 3 phase (Y) / 346-415 VAC | ||
Frequency (default inverter mode) | 50 Hz (adaptive) | ||
Frequency (set-able inverter mode) | 50Hz, 60Hz or last synced 50/60Hz (adaptive) | ||
Power maximum (continuous / overload (<15s) ) | 43,2 kW (54 kVA) / 72 kVA | ||
Current maximum/phase (continuous / overload (<15s) ) | 78ARMS / 104,4ARMS | ||
Current (maximum) Quick trip/phase (20ms) | 380A (6 x nominal) | ||
Hold up (Voltage dips) (before switching to battery) | > 5 ms @ 43,2 kW load | ||
THD | < 1.5 % at resistive load | ||
Output features | Module: Fuse in L and N , Hot pluggable 100 A MCCB, AC output individual screw terminals 70 mm2 for L1-L3, N & PE | ||
DC OUTPUT DATA | |||
Voltage (default) / (adjustable range) | 122,5 VDC / 97 - 145 VDC | ||
Power (maximum @nominal input) | 43,2 kW 2) | ||
Current (maximum @VOUT ≤ 48 VDC) | 400 A 2) | ||
Hold up time, maximum output power | >10ms; VOUT > 97 VDC | ||
Output features | Short circuit proof, Over voltage Shutdown Battery input /output connection to M10 bolt | ||
INPUT DATA | |||
AC Mains Input Voltage(3 phase Y) | 320-475 VAC, | ||
AC Current/phase(at nominal output voltage) (depending on module type) | 92-138 ARMS 4) | ||
Frequency (default: sync range) | 47-53 & 57-63 Hz | ||
Frequency (set-able: sync range) | 47-53 Hz, 57-63 Hz or both (adaptive) | ||
Power Factor / THD | > 0.99 at 50% load or more / < 3.5% | ||
DC Voltage nominal / extended range (no overload)3) | 102 - 145 VDC / 90 - 145 VDC | ||
DC Current (maximum) | 450 A / 648 A during overload (15s) | ||
Input features | Module : Fuse in L and N, Hot pluggable, Varistor, Hot pluggable 160 A MCCB, AC input individual screw terminals 70 mm2 for L1-L3, N & PE | ||
BATTERY & LOAD BREAKER | |||
2-pole battery breaker | 2*MCCB 630 A | 1*MCCB 880 A | |
2-pole load breaker | - | 1*MCCB 630 A | |
OPTIONS | |||
B-input maximum power (with FP2 HE, 2 kW rectifiers) | 48 kW | ||
Manual Bypass switch | 2*160 A | ||
OTHER SPECIFICATION | |||
Efficiency | >96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC)) | ||
Protection Class | IP 20 | ||
Operating temperature | -40 to +55°C (-40 to +131°F), humidity 5 - 95% RH non-condensing | ||
Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing | ||
Dimensions[WxDxH] / Weight | 600 x 600x 2000mm (23,7 x 23,7 x 78,8”) / 300 kg (1100 lbs) | ||
DESIGN STANDARDS | |||
Electrical safety | EN 60950-1, EN 62040-1 UPS safety | ||
EMC | ETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15 EN 61000-6-1 /-2/-4/-5 | ||
Environment | ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) Normal operating conditions to be as per IEC/EN 62040-3:2011 clause 4.2 Other operating conditions as per IEC 62040-3:2011 clause 4.3, must be advised 2011/65/EU (RoHS) & 2012/19/EU (WEEE) | ||
1) Output voltage ranges configured in factory and have individual keying in top chassis 3) 90 - 102 VDC: reduced performance - no power boost and increased voltage THD on AC output. | 2) AC load has priority. Maximum available DC output power and current is dependent on instant AC load and AC input voltage; i.e maximum 28 ,8kW/260 A at full AC power and nominal input for 230VAC. 4) If DC voltage is pulled below 97 V the input current may increase above this level |
* The indoor Rectiverter Cabinet with AC &DC feed in one cabinet
Related Products :
Solutions
We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.
FAQ :
1. How do you control the quality?
A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.
2. What is your minimum order quantity?
A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.
3. Can you introduce your company?
A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.
4. What are the advantages of your company?
A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.
5. Can i send samples?Report it to me along with the price?
A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.
6. How do your company deal with the problem on quality?
A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.
7 What about the quality ?
A:100% original with new package. we will test each item before posted to make sure each item with good quality.
8 How many months for guarantee ?
A: 1 year quality guarantee
9 How to deal with any inferior -quality goods ?
A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.