Innovative "1+3" functions
1 refers to the cooling and heating functions of air conditioning equipment. Energy-saving integrated computer
room air conditioners are integrated electric auxiliary heating air conditioners.
Ultra-large air volume, from 2P to 3P, the air volume is between 1550~1700m/3h
High sensible heat ratio, >80%, no condensation
Energy efficiency ratio is above the national level 2. (Integrated air conditioner level 2 energy efficiency standard 2.9)
3 refers to three additional functions.
Energy-saving fresh air function
Air purification function
Network monitoring function
Fresh air function
Integrated computer room air conditioners, precision air conditioners, and laboratory air conditioners have large air
volume fresh air function, which automatically introduces fresh air when the outdoor temperature is low to cool the
computer room equipment.
The fresh air function and cooling mode will not be turned on at the same time, and the mode switching is
determined by the electronic control
Fresh air enters the room through the filter
Air purification function
Use a double filtration system with a filtration level of G3, and various levels of filtration systems can be customized
according to customer needs
Remote network monitoring function Energy-saving integrated computer room air conditioners, precision air conditioners,
and laboratory air conditioners have reliable network monitoring functions
Unit parameter configuration table | ||||
order number | name | Model parameter | brand | |
1 | model | P07 | Heroth | |
2 | Unit performance | blowing rate (m³/h) | 6700 | |
3 | Cold volume (kw) | 27.9 | ||
Air-cooling ratio (w / m³ / h) | 4.16 | |||
4 | Input power in nominal refrigeration condition (kw) | 5.9 | ||
Quantity of compressor | 1 | |||
5 | Heat production (electric heating) (kw) | |||
6 | Input power in nominal heating condition (kw) | |||
7 | External residual pressure (static pressure) (Pa) | 50~350 | ||
8 | Temperature control range is (℃) | 18~31 | ||
9 | source | 380V 50Hz | ||
10 | cryogen | R22 | R410a R407c | |
11 | Energy saving way | Electronic expansion valve | ||
12 | energy management | 25.50.75.100 | ||
13 | Electrical heating type | electrode | ||
14 | Electric heating power (kw) | 5.85 | ||
15 | Type of humidifier | The electrode type | ||
16 | Humidification amount (kg) | 9 | ||
17 | Humidifier power (kw) | 5.8 | ||
18 | Humidifier pipe diameter: (Φ) | |||
19 | Humidity control range | 40~75 | ||
20 | an indoor unit | Evaporator type | Copper tube sleeve aluminum fin | |
21 | air filter | The initial effect | ||
22 | Indoor fan type | Low-noise centrifugal fan | ||
23 | Indoor fan power (kw) | |||
24 | External dimensions (indoor) | |||
25 | Unit weight | |||
26 | an outdoor unit | Condenser type | Copper tube sleeve aluminum fin | |
27 | Outdoor fan type | Low-noise axial flow fan | ||
28 | Outdoor fan power (kw) | |||
29 | External dimensions (outdoor) | |||
30 | Unit weight | |||
31 | other | Return to the wind | Horizontal air supply air, horizontal return air | |
32 | Indoor and outdoor machine link pipe | copper pipe | ||
33 | Link form | weld | ||
quantity | 2 | |||
caliber | ||||
34 | noise dB(A) | 54 | ||
35 | Remote control system interface | RS485/RS232 | ||
36 | With the power-off memory function | Automatic power-on after power outage and reset | ||
37 | With the temperature and humidity early warning function | The alarm parameters can be set | ||
Unit wiring |