Description
Dynamic Combined resistance Ozone Aging Test Machine is used to test the ozone environment, the characteristics of crack-resistant rubber, ozone resistance testing machine, can control and adjust the concentration of ozone environment, to determine the anti-ozone properties of the specimen.
Ozone aging tester can comply with the standard: JISK6259 ASTM1149 ISO1431
Technical Specification
Name | Dynamic Combined resistance Ozone Aging Test Machine | |||
Model | OC-250 | OC-500 | OC-800 | OC-010 |
Internal Dimension (mm) | 600*600*600 | 700*800*900 | 800*1000*1000 | 1000*1000*1000 |
Overall Dimension (mm) | 960*1150*1860 | 1180*1350*2010 | 1280*1550*2110 | 1500*1550*2110 |
Interior Volume (L) | 250 | 500 | 800 | 1000 |
Temperature Range | 0℃ ~ +100 ℃ | |||
Humidity Range | 30% ~ 98% RH | |||
Cooling Rate | Ambient ~ 0℃ within 20 min | |||
Ozone Concentration | 1~1000PPHM | |||
Sample Holder Rotate Speed | 0~10 r/min | |||
Airflow Rate | 0 ~ 60L/min | |||
Clamps Tensile Stretch | 5%~35% | |||
Cooling system | Mechanical compression refrigeration system | |||
Refrigerating unit | French TECUMSEH compressor | |||
Refrigerant | R404A, R23 | |||
Heating Element | Nichrome heater | |||
Controller | Programmable color LCD touch screen controller Ethernet connection, PC Link | |||
Temperature Sensor | PTR Platinum Resistance PT100Ω/MV A-class, accuracy 0.001℃ | |||
Humidity Sensor | Dry and wet bulb sensor | |||
Gas Sensor | Ozone gas sensor | |||
Ozone Generator | Silent discharge type ozone generator | |||
Air Circulation | Centrifugal wind fan | |||
Door Lock | Electromagnetic lock | |||
Sample Holder | Static + dynamic combined sample holder | |||
Safety Device | Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Refrigerant High-pressure Protection; Water Shortage Protection; Earth Leakage Protection | |||
Thermal Insulation | Polyurethane foam and insulation cotton | |||
Observation Window | Interior lighting, double-layer thermostability silicone rubber sealing | |||
Power Supply | 380V 50Hz | |||
Standard | ISO1431;ASTM 1149;IEC 60903 ;IEC60811-403;JIS K6259;ASTM D1171 | |||
Maximum Noise | 65 dBA | |||
Environmental Conditional | 5℃~+35 ℃ ≤85% RH |
Main technical parameters
1.Ozone aging environmental machine temperature range:0℃–100℃
2.Temperature fluctuation:±0.5℃ ±2.0℃
3.Density of ozone :1~1000pphm ±10%
4.The lifting frequency of the sample frame:0-10r/min(optional)
5.Air flow velocity:12~16mm/s
6.Test gas flow:0~60L/min
7.Sample frame speed:360 degree rotating sample frame(rotate speed 1~10 rpm or purchase adjustable model
Factory Acceptance Insection Includes The Following
1. Whether the appearance of the product equipment is complete and the size meets the requirements
2. Inspect performance and parameter according to datasheet
3. Whether the accessories of the equipment parts are complete and complete
4. Conduct special testing and debugging of the entire equipment for different countries and regions.