IPX7 Waterproof Test Chamber
Description
IPX7 waterproof test chamber is used to test the sealing and water-proof property for external lighting, signal device, vehicle lamps shell protection.
Waterproof ipx7 water chamber provides a realistic water spray simulation condition of electronic products and components.
Main Technical Parameter
Name | IPX7 Waterproof Test Chamber |
Internal dimension | Diameter 600mm *Height 1500mm. |
Chamber material | SUS#304, thickness 2.5mm |
Water depth | Simulate 50m depth by air compressor |
Water pressure | Ambient to 0.5MPa, pressure gauge accuracy 0.25 degree |
Timer | 0 ~ 99min, 99sec |
Sample lift device | Portable stainless steel basket |
Water level display | Water pipe with scale |
Open mode | pneumatic lift with safety lock. |
Protection device | Pressure protection and anti-explosive device, water drain and pressure release device |
Safety protection | Power overload protection, short circuit protection, grounding protection, alarm display |
Nominal power | 3500W |
Power Supply | AC380V 50HZ |
Configuration
| |
Test Area | Footstand |
| |
Control Panel | Safe Lock |
IPX7
Method name: Short time immersion test.
Test equipment and conditions: Immersion tank. The dimensions shall be such that the sample shall be placed in the immersion tank at a distance of at least 1m from the bottom of the sample to the surface of the water. The distance from the top of the sample to the water surface should be at least 0.15m.
Testing time: 30 min.
IPX8
Method name: Continuous diving test.
Test equipment, test conditions and test time: The severity shall be higher than IPX 7 as agreed by the buyer and the seller.
Note: Many outdoor electronics also emphasize the ability to float.
Standard
Ipx7 test equipment meet standard
IEC60529 degree of protection provided by enclosures (IP Code) of the IPX7 IPX8, IEC60884-1, IEC60335-1, IEC60598-1.
Application
Ipx8 immersion tank,Assessment of enclosures and sealing element whether can ensure good performance of equipment and components after the water test or during the test.