Current 23a Environmental Test Room Simulation High Altitude Low Pressure Test Chamber
Simulated high altitude low pressure test chamber (plateau environmental test chamber)
|
|
Box specification |
1, inner size: 800 (width) × 800 (deep) × 800 (height) mm
2, the outer dimensions are about: 1100 (width) × 1050 (deep) × 1680 (height) mm + 150mm casters; subject to the real thing;
3. Control panel: The control panel is located at the lower part of the machine (as shown in the figure);
4, open the door: single door from right to left;
5, compartment: inside the second layer, the bottom 50mm first layer, the above is divided into two layers, with two stencils;
6, can be window: the door with a window, specifications 350 * 350mm;
7. The sealing material is: high temperature resistant silicone strip;
8. The structure of the box is: the upper part is the product room, and the lower part is the electric control box and vacuum pump installation;
9. Vacuum pump installation method: the vacuum pump is installed in the lower part of the machine;
10. The inner box material is: high temperature resistant SUS304# stainless steel industrial board, the thickness of the steel plate is 5.0mm, and the treatment is vacuumed without deformation;
11. The outer box is made of: 1.2mm thick cold-rolled steel plate, and the outer surface of the steel plate is treated with double-sided paint (white);
12, insulation material: fiber rock wool, good insulation performance, thickness 100mm;
13. Equipment use environment: working environment temperature is 5 to 25 °C, working environment humidity is 35% to 75%;
14. The movable caster and adjustable fixed foot cup are installed at the bottom of the machine.
|
Temperature control system |
1. The temperature controller is a digital display instrument (Taiwan Taisong instrument), single-point temperature control, automatic calculation, PV/SV simultaneous display, button setting;
2, timing function: 0-9999 hours / min / sec, warm to the timing, time to stop heating, and alarm prompts;
3. The temperature sensing line is (K) type;
4, the output is 3-32V;
5. The current controller is: SSR solid state relay;
6. Heating method: heat radiation with three sides heating; (left, right, and bottom sides of the inner box wall)
7. The heating element is: stainless steel high temperature resistant heating tube;
8, temperature range: normal temperature +15 ~ 100 °C adjustable;
9, instrument control accuracy: ± 0.5 ° C;
10. Instrument accuracy display: 0.1 °C;
11, the temperature deviation inside the box: ± 6 ° C. (no vacuum test).
|
Seal and vacuum display |
1. This machine adopts high-density silicone sealing strip to seal at the door, and the sealing performance of the whole machine is good;
2. Use Panasonic digital display vacuum gauge to display the vacuum inside the box; Negative pressure display pressure gauge
3. The vacuum sensor is: automatic air pressure sensing;
4. Vacuum range: 0.0KPa to -100.0KPa;
5, vacuum pressure leakage rate: about 1.0KPa per hour;
6. The vacuum control mode is: automatic control, reaching the upper limit set value stop, lower than the lower limit start, and thus circulating to maintain the optimal low pressure state;
7. Pressure display mode: For relative display, if the test vacuum is 70.0KPa, the standard air pressure is 101.3KPa-70.0KPa=31.3KPa, and the vacuum gauge is set to -31.3KPa. The set data is pumped away. Pressure, other parameters are calculated in the same way;
8. Vacuum pump configuration: one XD-20 vacuum pump, voltage 220V, power 0.9KW;
9, vacuum pump exhaust device, need to be exhausted to the outside (your company to handle it).
|
Over temperature and circuit protection system |
1. Over-temperature protection system: independent over-temperature protection device, when the over-temperature protection set temperature is exceeded, the heating supply is automatically stopped, thus protecting the safety of products and machines;
2, circuit protection system: phase sequence protection, ground protection, overload protection, circuit breakers, etc..
|
machine power supply |
1, voltage 380V/50Hz three-phase five-wire system;
2, current 23A
3, power 6.0KW
4, except for rice cooker power
|
Monitoring System |
1. Make two 220V/3KW sockets in the box and use them for the rice cooker on behalf of the electricity;
2. The rice cooker power supply line monitors the voltage, current and power (the monitoring table is shown in the figure).
|