Programmable Constant Temperature And Humidity Test Chamber 150l Stainless Steel
Product Usage:
Mainly for the testing of electronic components, industrial materials, finished products in the R & D, production, inspection of all aspects of the test provide constant damp heat, complex high and low temperature alternating test environment and test conditions, suitable for electronic appliances, communications, chemicals, hardware, rubber, furniture , toys, scientific research and other industries.
Temperature and humidity control range:
The main technical parameters:
Model | JD-8001B-80 | JD-8001B-150 | JD-8001B-225 | JD-8001B-408 | JD-8001B-800 | JD-8001B-1000 | ||||||||||||||||||
Inner box size(W*H*D)mm | 400*500*400 | 500*600*500 | 500*750*600 | 600*850*800 | 1000*1000*800 | 1000*1000*1000 | ||||||||||||||||||
Carton size(W*H*D)mm | 920*1360*970 | 1020*1460*1070 | 1020*1610*1170 | 1120*1710*1300 | 1500*1850*1310 | 1500*1850*1470 | ||||||||||||||||||
Inner box volume | 80L | 150L | 225L | 408L | 800L | 1000L | ||||||||||||||||||
Temperature and humidity range | Low temperature range:-70℃/-40℃/-20℃/0℃;High temperature range:100℃/150℃;Humidity range:20%RH—98%RH | |||||||||||||||||||||||
Temperature and humidity uniformity | Temperature uniformity:±2℃;Humidity uniformity:±3%RH | |||||||||||||||||||||||
Heating time | 100℃ | 150℃ | 100℃ | 150℃ | 100℃ | 150℃ | 100℃ | 150℃ | 100℃ | 150℃ | 100℃ | 150℃ | ||||||||||||
25min | 35min | 30min | 40min | 30min | 40min | 30min | 40min | 35min | 45min | 35min | 45min | |||||||||||||
Cooling time(min) | 0 | -20 | -40 | -70 | 0 | -20 | -40 | -70 | 0 | -20 | -40 | -70 | 0 | -20 | -40 | -70 | 0 | -20 | -40 | -70 | 0 | -20 | -40 | -70 |
30 | 45 | 65 | 100 | 30 | 45 | 65 | 100 | 30 | 45 | 65 | 100 | 30 | 45 | 65 | 100 | 30 | 45 | 65 | 100 | 30 | 45 | 65 | 100 | |
Power supply(kw) | 4.5 | 5.0 | 5.5 | 6.5 | 5.0 | 5.5 | 6.0 | 7.5 | 5.5 | 6.0 | 6.5 | 8.5 | 6.0 | 6.5 | 7.0 | 9.5 | 6.5 | 7.0 | 7.5 | 10.5 | 7.0 | 7.5 | 8.0 | 11.5 |
weight | 200 kg | 250 kg | 300 kg | 400 kg | 600 kg | 700 kg | ||||||||||||||||||
Inner box material | Stainless steel matte line treatment | |||||||||||||||||||||||
Outer box material | Stainless steel plate / color steel plate | |||||||||||||||||||||||
Insulation material | Rigid foam and glass wool | |||||||||||||||||||||||
Wind cycle | Centrifugal fan + broadband forced air circulation (up and down push) | |||||||||||||||||||||||
Cooling method | Air-cooled, single or cascade refrigeration, compressor (using French Taikang fully enclosed compressor or German BITZER semi-hermetic compressor) | |||||||||||||||||||||||
The refrigerant | R404A R23A | |||||||||||||||||||||||
Heater | Nichrome electric heating wire heater | |||||||||||||||||||||||
humidifier | Stainless steel sheathed humidifier | |||||||||||||||||||||||
Water supply method | Pump lift | |||||||||||||||||||||||
Accessories | 1 test hole cover (φ50), 2 shelves, 5 gauze, 5 filter cotton | |||||||||||||||||||||||
protective device | No fuse switch, protection wire, over temperature protection, anti-dry protection, water shortage protection, liquid level protection, compressor overpressure, overheating, overcurrent protection, emergency shutdown, etc. | |||||||||||||||||||||||
power supply | 1φ3w AC220V ±10% 50/60Hz 3φ5w AC380/415V ±10% 50/60Hz |
Note:
1. The test method for uniformity of temperature and humidity distribution is measured according to the effective space of 1/10 distance from the inner box.
2. can be customized according to customer size and size.
Implementation and satisfaction criteria:
GB/T2423.1-2001 IEC60068-2-1.1990 GB11158
GB/T2423.2-2001 IEC60068-2-2.1974 GJB150.3
GB/T2423.3-93 GB10589-89 GJB150.4
GB/T2423.4-93 GB10592-89 GJB150.9
image: