Specifications
Brand Name :
iqualitrol
Model Number :
QTS3-56A/B/C
MOQ :
1 Set
Supply Ability :
5 Sets per Month
Delivery Time :
30 Working Days
Packaging Details :
Plywood Box
Payment Terms :
T/T
color :
white
Interior dimensions :
400 ×350× 400mm
Cooling Method :
Cascade Refrigeration System
Ambient Temperature :
5ºC~30ºC
Description

Three Zone QT3 Thermal Shock Testing Chamber

Brief Introduction:

Q1-Test Thermal Shock Test Chamber QT3 Series is used to test products in alternating extremes of high and low temperatures in order to observe changes in product characteristics and failure occurrence,the applicable the object material, including metals, plastics, rubber, electronic, ..., etc., can be used as the basis of its product improvement or reference.

QT3 series air-to-air thermal shock chambers circulate cold, hot, or ambient air as needed. The conditioned air is pre-cooled or pre-heated beyond the set point, allowing quicker recovery of the desired condition after transfer

Features:
1. Automatically setting of pro-cooled and pre-heated air.
2. Testing samples don't move, cable port is available for power on testing.


3. Powerful interactive touch screen controller, easy operation and setting
4 .High accurate temperature recovery with PID auto tuning, High formula memory capacity can store 120 patterns, 9999 cycles, setting time for each pattern is 9999 Hrs 59 Mins


5. Auto defrost function
6. Three sections: High temperature zone, low temperature zone, testing zone.

Testing Standards:
MIL-STD-883E Method 1011.9 Thermal Shock
MIL-STD-202G Method 107G thermal Shock
JIS C 0025 Change of temperature
IEC 61300-2-47 Tests-Thermal Shocks
JESD22-A104C Temperature cycling
GB/T 2423.22-2012 Test N: Change of temperature

Chamber Dimensions:

Model Interior dimensions
(W ×H × D)
Interior Volume Exterior dimensions
(W ×H × D)
Specimen loading weight
QTS3-56A/B/C 400 ×350× 400mm
15.7"×13.8"×15.7"
56L 1450× 1950 ×1600mm
57.1" ×76.8" ×63.0"
2.5Kg
QTS3-80A/B/C 500 ×400× 400mm
19.7"×15.7"×15.7"
80L 1550× 2050 ×1600mm
61.0" ×80.7" ×63.0"
5.0Kg
QTS3-150A/B/C 600 ×500× 500mm
23.6"×19.7"×19.7"
150L 1650× 2150 ×1800mm
64.9" ×84.7" ×70.9"
7.5Kg
QTS3-225A/B/C 750 ×600× 500mm
29.5"×23.6"×19.7"
225L 1850× 2250 ×1800mm
72.8" ×88.6" ×70.9"
7.5Kg


Technical Specifications:

Structure Pre-cooling Zone, Pre-heating Zone, Testing Zone (Selectable 2-Zone or 3-Zone Test for stationary object test)
Damper Device Forced Air Damper
Test Cabinet Temperature A= -35ºC~0ºC/60ºC~150ºC B= -55ºC~10ºC/60ºC~150ºC C= -65ºC~10ºC/60ºC~150ºC
Interior Material SUS#304 Stainless Steel
Exterior Material stainless steel with environmentally baking paint
Testing Shelves Stainless Steel Plate
Refrigeration Cascade Refrigeration System
Cooling Method Water/Air Cooling
Ambient Temperature 5ºC~30ºC
Pre-heating Temperature 80ºC~200ºC
Pre-cooling Temperature -40ºC (-60ºC/-75ºC)~-10ºC
High Temp. Shocking 60ºC~150ºC
Low Temp. Shocking A=―35ºC~0ºC
B=―55ºC~10ºC
C=―65ºC~10ºC
Temp. Uniformity Less than ±2ºC
Transition time <10 seconds
High Temp. Recovery time RTºC~150ºC/5min
Low Temp. Recovery time RTºC~-75ºC/5min
Pre-heating Time 40min (30min for 56L)
Pre-cooling Time 80min (60min for 56L)
Controller Powerful interactive LCD touch screen controller
Setting Range Temperature: -200ºC~300ºC
Time: 0H1m~9999H59m
Cycle: 1~9999cycle
Resolution Temperature: 0.01ºC
Time: 1min
Control Method PID+SSR
Power supply AC380V/50Hz/3P
Accessories Viewing Window, Cable Port, Chamber Illumination,
LCD touch screen controller, Power cable
Security System Overheat Protector, Compressor overload protector, Controller protector, Motor overload protector


Note:
1. Ambient temperature of +23ºC and a cooling water temperature of +25ºC
2. During pre-heating, prevention for temperature heat-up may be worked
3. Performance shown above conforms to IEC61300-2-47
4. Temperature heat-up/pull-down time is applicable only during independent chamber operation.

Send your message to this supplier
Send Now

Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System

Ask Latest Price
Brand Name :
iqualitrol
Model Number :
QTS3-56A/B/C
MOQ :
1 Set
Supply Ability :
5 Sets per Month
Delivery Time :
30 Working Days
Packaging Details :
Plywood Box
Contact Supplier
Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System
Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System

DongGuan Q1-Test Equipment Co., Ltd.

Site Member
8 Years
guangdong, dongguan
Since 2000
Business Type :
Manufacturer, Exporter
Total Annual :
700000-1000000
Employee Number :
50~75
Certification Level :
Site Member
Contact Supplier
Submit Requirement