Constant temperature humidity test chamber 3 layers type is used for the product according to the national standards or set requirements, the user changes in low temperature, high temperature, temperature and humidity and its circulation condition, physics and other related characteristics of product environmental simulation test, test, through testing, to judge the performance of the products, whether can still meet predetermined requirement, so that for product design, improve, identification and factory inspection.
Parameters :
Model Name | PT-2093 Temperature & Humidity Test Chamber 80L, 3 Chambers Type |
Inner Cabinet Size | 40*40*50cm(W*D*H), 3 layers |
Outer Caninet Size | 110*130*218cm(W*D*H) |
Temperature Range | -20℃ to 100℃ |
Temperature Fluctuation | ≤±0.3℃ |
Temperature Departure | ≤±2℃ |
Humidity Range | 30%~98%. |
Humidity Fluctuation | ≤±2%R.H. |
Humidity Uniformity | ≤±3% R.H.(at condition ≥75%R.H.) ≤±5% R.H.(at condition<75%R.H.) |
Heating Time | -20℃→+100℃: 2-3℃/min |
Cooling Time | +20℃→-20℃: 0.7-1℃/min |
Test Environment | ambient temperature is +25℃, relative humidity not over than 85%, and there is no sample in the test chamber |
Source Of Power Supply | 3 phase 5 line ,AC 380V, 30A |
Meet Standards:
GB/T11158-2008,GB/T10589-2008, GB/T10592-2008, GB/T10586-2006, GB/T2423.1-2008 Test A, GB/T2423.2-2008 Test B
GB/T2423.3-2006, GB/T2423.4-2008,GB/T2423.22-2002, IEC60068-2-1:2007
IEC60068-2-2:2007, GJB150.3 ; GJB150.4 ;GJB150.9
IEC68-2-1 Test A; IEC68-2-2 Test B
Structural Features :
1. Insulation envelope
1) Outer wall material: cold rolled steel plate baking paint.
2) Inner wall material: 304 stainless steel.
3) Box insulation material: rigid polyurethane foam.
4) Door insulation material: rigid polyurethane foam.
2. Air Adjust Channel
1)Centrifugal fan of air conditioning channel:
2) Heater, humidifier, evaporator, feed outlet, temperature sensor.
3. Standard Configuration of Test Chamber
4. Chabmer Door
5. Control panel controller display screen, overtemperature protection setting device
6. Refrigeration unit of mechanical room, water receiving tray and drainage hole
7. Distribution control cabinet distribution board and exhaust fan
8. Heater heating system: bare wire heating wire heating air circulation mode
9. Humidifier shallow groove boiler humidification system.
10. Power cord holes and drain holes are located on the back of the cabinet
Refrigeration system :
1. Working mode mechanical refrigeration.
2. The original refrigeration compressor is imported from France "Tecumseh" low-temperature and high-efficiency full-density compressor.
3. Evaporator fin type multi - stage automatic load capacity adjustment.
4. Condenser air-cooled separation type.
5. Expansion system: volumetric controlled refrigeration system (capillary).
6. Evaporative condenser stainless steel brazing plate heat exchanger.
7. The controller of the control system automatically adjusts the operating condition of the refrigerator according to the test conditions.
Evaporation pressure control valve.
Compressor return air cooling circuit
8. Refrigerant dupont R404a environmental refrigerant (ozone depletion index: 0)
Electrical control system :
1. Independently developed control system:
2. Temperature and humidity controller:
3. Controller Specification :
4 . Screen Display Function :
4. program capacity and control function