Medical Masks Flammability Tester is used to test the flammability of medical masks, to ensure the safety of masks to wear in. Medical Masks Flammability test Chamber complies with EN 149, GB 2626, GB 19083.
The burner ignites the specimen automatically, and ignition time is programmable; after-flame time and afterglow time are timed automatically and shown on the display. The user-friendly design of the control panel, Touch screen is equipped to make the operation conveniently, the test results are displayed on the screen after the vertical flammability test.
Comprises a draft-free stainless steel flammability chamber with an observation window for easy test viewing. human-head-shaped Specimen masks holders, burner and associated hardware are dependent on the test standard and must be specified.
Weight 65 kg
Power 220 /110 V 50/60 Hz
Burner Complied with ISO 6941
Burner to specimen distance 20 mm
Time Display and accuracy 0-999.9s, 0.1s
Moving Rotating at a linear speed of 60mm/s
Dimensions 650 x 580 x 1120 mm (L x W x H)
System and Display Programmable PLC and touch screen controls
Medical Masks and Protective Clothing: EN 149, GB 2626, ASTM F2100, 16 CFR Part 1610, GB 19082 – 2009, GB/T 5455, EN 14126 – 2003, EN14325 4.14/4.15, EN 13274-4
ASTM D6413, CALIF TB117, DOC-FF 3/71, FTMS 191-5903, CPAI 84