Principle: On a solid surface of insulating material, between the required size (2mm × 5mm) platinum electrode, a voltage is applied. At the same time, timed (30s), set height (35mm) and dropping a predetermined volume of contaminated liquid droplets (0.1% NH 4 CL ) to evaluate the endurance capacity of the surface of solid insulating materials under the combined effects of electric and contaminated media, accordingly, its comparative tracking index (CT1) and resistance to tracking index (PT1) is tested.
Suitable for the research, production and quality control for lighting, low voltage electrical appliances, household appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, information technology equipment, and also suitable for insulation, plastic, electrical connections, accessories industry. |
Standards: IEC60112, UL746A, ASTMD3638, DIN53480, GB4207 |
|
Model | GT-MC36 |
Controller | 7 inches PLC |
Voltage Display | Digital voltage modules direct touch-screen display |
Current Display | Digital current module direct touch-screen display |
Dimensions | 1120 x 600 x 1020(L x W x H) |
Inner Capacity | ≥0.5cube |
Electrode Material | Pt |
Electrode Size | 2mm x 5mm x 35 mm |
Electrode Pressure | 1.00N |
Electrode Distance | 4.0mm |
Droplet Volume | 50 drop/1cm3 |
Droplet Height | 35mm(can be set) |
Droplet Time | 30s±0.1(can be set) |
Droplet Amount | 1~9999(can be set) |
Test Voltage | 50V ~600V(can be set) |
Power Voltage Difference | 1.0A ± 0.1A <8% |
Tracking Evaluation | 0.50A ±0.05A |
Accessories
Standard Accessories | 1 pc | Standard electrode |
1 pc | Imported micro pump | |
2 pcs | Tempered glass | |
1 pc | Standard solution | |
2.5metres | Exhaust duct |