ISO 13982 Protective Clothing and Masks Leakage Tester
Application
Protective mask leakage tester to test protective clothing against solid airborne particles including radioactive contamination. The machine use “inward leakage in %”, ratio of the concentration of contaminant in the ambient atmosphere to the concentration of the contaminant in the suit, to evaluate the quality of protective clothing.
Controlling & Analysis system
1. Central control console, computer programmed control, prompting experiment process 2. Monitoring test data automatically, calculating individual test inward leakage rate, total inward leakage rate, average inward leakage automatically, output testing result in various way
Model | GT-RA08 | |
Environmental Requirement
| Working temperature | (20±5)℃ |
Humidity | ≤60% | |
Used space | ≥4000×5000×3000mm, water in/drain pipe, room with good ventilation | |
Walked-in Testing Room
| Inner effective size | 1800mm×1500mm×2100mm(L×W×H) |
Outer size of testing room | 1950mm×1650mm×2500mm(L×W×H) | |
Control cabinet | 700mm×700mm×1600mm(L×W×H) | |
Environmental Analog detection system
| Particle aerosol concentration | (10±1) mg/mPP3 |
Aerodynamics size distribution of particle | (0.02~2)μm | |
Mass median diameter | About 0. 6μm | |
Concentration variation in effective space | ≤10% | |
Occurrence amount | ≥100L/min | |
Particle Concentration Detector
| 2sets | |
Dynamic range | (0.001~200)mg/m3 | |
accuracy | ±1% | |
response time | ≤500 ms | |
Horizontal Pedal Drive Test-bed | Running speed | (5±0.5)km/h |
Other Accessories | Air duct circulation and maintenance of cleaning equipment | |
Standards | GB/T 29511-2013 Protective clothing- Chemical protective clothing against solid particulates4.3.1, Annex A GB 2626-2019Respiratory protection—Non-powered air-purifying particle respirator 6.4 GB 19083-2010Technical requirements for protective face mask for medical use ANNEX B ISO 13982, BS EN ISO 13982 , EN149, EN 1073-1-2016 |