1. Maximum Contact Rating: 125VAC/16A, 250VAC/8A, 24VDC/20A
2. Lead wire pull Strength
3. 50N applied from lead to lead for 1 minute. No slip-off or rupture.
4. Dielectric Strength between Contacts
Each device will withstand a nominal 660 VAC for 1 minute or 720 VAC for 1 second during open status
with no arc, and a current leakage less than 10mA between leads (or terminal)
5. Contact Resistance
50 mohm maximum (milliohm meter)
6. Insulation Resistance
The resistance between the leads and insulation sleeve is >100 Mohm with 500 VDC at 25 °C.
7. Seal Test
Each device is submerged water for 5 seconds at temperature >85 °C but less than boiling point.
No air bubbles emerge.
Opening and closing Temperature
Model | Open Temp. | Close Temp. | Model | Open Temp | Close Temp. |
17AM-D 60℃ | 60±5℃ | 45±10℃ | 17AM-D 120℃ | 120±5℃ | 75±15℃ |
17AM-D 65℃ | 65±5℃ | 50±10℃ | 17AM-D 125℃ | 120±5℃ | 80±15℃ |
17AM-D 70℃ | 70±5℃ | 50±12℃ | 17AM-D 130℃ | 130±5℃ | 85±15℃ |
17AM-D 75℃ | 75±5℃ | 55±12℃ | 17AM-D 135℃ | 135±5℃ | 85±15℃ |
17AM-D 80℃ | 80±5℃ | 55±15℃ | 17AM-D 140℃ | 140±5℃ | 90±15℃ |
17AM-D 85℃ | 85±5℃ | 60±15℃ | 17AM-D 145℃ | 145±5℃ | 95±15℃ |
17AM-D 90℃ | 90±5℃ | 60±15℃ | 17AM-D 150℃ | 150±5℃ | 95±15℃ |
17AM-D 95℃ | 95±5℃ | 65±15℃ | 17AM-D 155℃ | 155±5℃ | 100±15℃ |
17AM-D 100℃ | 100±5℃ | 65±15℃ | 17AM-D 160℃ | 160±5℃ | 105±15℃ |
17AM-D 105℃ | 105±5℃ | 70±15℃ | 17AM-D 165℃ | 165±5℃ | 110±15℃ |
17AM-D 110℃ | 110±5℃ | 70±15℃ | 17AM-D 170℃ | 170±5℃ | 115±15℃ |
17AM-D 115℃ | 115±5℃ | 75±15℃ |
|
|
|
|
|
|
|
|
|