Shielding Absorbing Material For IT Devices
Ziitek Electronic Material and Technology Ltd. provides product solutions to equipment product which generates too much heat affecting its high performance when using. Plus thermal products can control and manage heat to keep it cool to some extent.
Applications:
Provide EMC material solutions for EMI & EMS issue for IT devices
1.1 Metal rubber absorber to conduct different microwave resonance frequency
within the property of loss energy
1.2 Noise suppressor for electric devices(Smart phones, Tablets, PCs and etc)
1.3 Receiver sensitivity improvement of PEN input (inductive coupling type)
1.4 Enhancement of NFC&WPC(PMA/WPC) function within electric devices
TIFTM900B-10 Series Shielding Absorbing Materials | |||
Classification | Unit | Values | Test Method |
Color | NA | Gray | Visual |
Effective frequency | Hz | 10GHz - 6GHz | NA |
Permeability(at 1MHz) | μ' (1MHz) | 50±10 | E4991A |
Specific gravity | g/cm3 | 4.3 | ASTM D297 |
Surface resistance(min.) | Ω | >1 x 1012 | ASTM D257 |
Hardness | Shore A | 40-60 | ASTM D2240 |
Thermal conductivity | W/mK | 1.0 | ASTM D5470 |
Temperature range | °C | -40 to +150 | NA |
Storage conditions | - | 0-30°C/60%±10R.H | NA |
Shelf life | month | 12 | NA |
Flame Rating | - | UL 94 V-0 | E331100 |
Standard thickness | mm | 0.5mmT-5mmT | |
Standard size | mm | 200*400mm |
Ziitek Culture
Quality :
Do it right the first time, total quality control
Effectiveness:
Work precisely and thoroughly for effectiveness
Service:
Quick response, On time delivery and Excellent service
Team work:
Complete teamwork, including sales team, Marketing team, engineering team, R&D team, Manufacturing team, logistics team. All is for supporting and servicing a satisfy service for customers.
Q&A
Q: What's the thermal conductivity test method given on the data sheet ?
A: All the data in the sheet are actual tested.Hot Disk and ASTM D5470 are utilized to test the thermal conductivity.
Q: How do I request customized samples?
A: To request samples, you can leave us message on website, or just contact us by send email or call us.
Q: What's the thermal conductivity test method given on the data sheet ?
A: All the data in the sheet are actual tested.Hot Disk and ASTM D5470 are utilized to test the thermal conductivity.
Q: How to find a right thermal conductivity for my applications
A: It depends on the watts of power source , ability of heat dissipation. Please tell us your detailed applications and the power, so we can recommend most suitable thermal conductive materials.