Radial Leaded Tin Plated Copper Housed PTC Thermistor Limit Temperature Sensors 100°C
Description Of The PTC Thermistor Limit Temperature Sensors 100°C
PTC thermistor 100C designed as limit temperature sensor , to sensing temperature and send single to pcb logger , measuring,controlling,limiting temperature in all kinds of applications such as motor,industrial,new energy car etc.Good curve can ensure long term stability and precision temperature reading.Custom made is available.
Features Of The PTC Thermistor Limit Temperature Sensors 100°C
* Two coating form : A- Lead type, B- Metal terminal type
* Protection temperature range 30~130 deg
* No need reset after protected
* Precision measuring
* Good stability
* Fast response on temperature change
Application Of The PTC Thermistor Limit Temperature Sensors 100°C
* Industrial inverter
* Motor
* Transformer
* Power parts
* Switch power supply
* New energy filed
* Electric thermostat
Dimension Of The PTC Thermistor Limit Temperature Sensors 100°C(mm)
Ordering info Of The PTC Thermistor Limit Temperature Sensors 100°C
Sensing Temperature | TDK EPCOS | AMPFORT |
60℃ | B59052D1060A040 | PTB02S6101FR1 |
70℃ | B59052D1070A040 | PTB02S7101FR1 |
80℃ | B59052D1080A040 | PTB02S8101FR1 |
90℃ | B59052D1090A040 | PTB02S9101FR1 |
100℃ | B59052D1100A040 | PTB02S1001FR1 |
110℃ | B59052D1110A040 | PTB02S1101FR1 |
120℃ | B59052D1120A040 | PTB02S1201FR1 |
Welcome to contact us to get more info.
Reliability Of The PTC Thermistor Limit Temperature Sensors 100°C
Test | Standard | Test conditions | ∆R25/R25 |
Electrical endurance, constant | IEC 60738-1 | Storage at Vmax and Top,max (@ Vmax) Test duration: 1000 h | < 25% |
Damp heat | IEC 60738-1 | Temperature of air: 40 °C Relative humidity of air: 93% Duration: 56 days Test according to IEC 60068-2-78 | < 10% |
Rapid change of temperature | IEC 60738-1 | T1 = Top,min (0 V), T2 = Top,max (0 V) Number of cycles: 5 Test duration: 30 min Test according to IEC 60068-2-14, test Na | < 25% |
Vibration | IEC 60738-1 | Frequency range: 10 to 55 Hz Displacement amplitude: 0.75 mm Test duration: 3 × 2 h Test according to IEC 60068-2-6, test Fc | < 5% |