Specifications
Brand Name :
PANRAN
Model Number :
PR231B-1
Certification :
CE,ISO9001
Place of Origin :
Tai'an,China
MOQ :
1 pcs
Price :
negotiable
Payment Terms :
TT, LC, Visa, Western Union, Alipay, Trade assurance, E-checking
Supply Ability :
20 pcs / month
Delivery Time :
15~25 working days
Packaging Details :
Standard export Packing (aluminium alloy, laminated wood, carton)
Cell type :
7.4V 4400mAh, Rechargeable lithium battery
Preheating time :
10 minutes after preheating
Charging time :
5 hours
charging source :
100~240V AC,50~60Hz
Working temperature :
-10℃~50℃
Working time :
≥20 hours(24V power off)
Humidity :
0~80%,Non condensing
Calibration period :
2 years
Size :
225mm*130mm*53mm
Weight :
990g
parameters of measurement :
Voltage,Current,Ohm,Thermal couple,Cold end compensation,Thermal resistance,Standard temperature,ρ-value,Frequency,Temperature difference
parameters of the output function :
Voltage,Current,Ohm,Thermal couple,Thermal resistance,Frequency / Pulse,Precision temperature control,24V output
Description

Process Calibrator Can Measures 10 Thermocouple Types, 7 RTD Types, Plus Volts And Ohms

The PR231 series products have excellent performance indicators, numerous practical functions and powerful human-interface . The series includes two levels of accuracy, 0.01% and 0.02%. The measure and source are completely isolated, in addition to the general functions of a two-channel calibrator, it also has the measurement function of ρ value and standard temperature. The enhanced type also features a temperature difference test and a precision temperature control function. It is compact in design, portable, and suitable for on-site and laboratory applications, making it the first choice for temperature calibration.

RTD Types Thermocouple Calibrators

  • Products Features

1. Temperature difference measurement with accuracy of 0.003 ° C

PR231A calibrator measures the temperature difference between two points in space without other instruments. When the function is used, the four terminals of the source function be used as measurement terminals and the process of the temperature difference data acqusition can be completed within 0.4 Seconds, which effectively improves the accuracy of

the measurement. The stability can also be calculated in real time during the test

RTD Types Thermocouple Calibrators

2.Standard temperature measurement

Different from ordinary TC and RTD measurement, the standard temperature measurement may use the certificate value for temperature traceability. The input signals include:STC - > S type, R type, B type, T type.SPRT-> Rtp = 25Ω or Rtp=100Ω.

RTD Types Thermocouple Calibrators

3.Reference Junction Compensation

The reference junction compensation methods of the PR231 series calibrator are very flexible and three methods are available, namely internal, external, and customized. The external reference junction adopts Grade A Pt100, and can input the certificate value for the reference junction data correction. When PR231 series calibrator is combined with PR1501 temperature equalization compensation module, a reference junction compensation error of less than 0.07°C can be obtained.

RTD Types Thermocouple Calibrators

4.Precision temperature control function

Using the precision temperature control function, temperature closed-loop control of the constant temperature equipment can be realized instead of the high-precision PID controller. In the case that the constant temperature equipment and grid voltage are satisfactory to the conditions, the temperature fluctuation of the equipment can be better than 0.02°C /10min (thermostatic bath).

5.ρvalue measurement

The PR231 series calibrator can measure the duty factor of the periodic square signal and can be used to verify and calibrate the PID parameters of various digital temperature indicating regulators for time proportional output, and meet the requirements of JJG 617-1996 Verification Regulation of Digital Temperature Indicators and Controllers.

6.Thermal calculator

It is used to achieve various conversions between electric and temperature. The conversion support a variety of TCs, RTDs and thermistors.

7. Value Settings

The PR231 series calibrator has the most flexible and convenient output value setting method. It is possible to directly set the output value through the numeric keypad, or to increase the increment setting by pressing the direction key. In addition, the device has an editable phase step or slope value setting method.

8.Sinusoidal signal output function

The verification/calibration of some process loggers, especially mechanical recorders, usually involves the operation test. In this case, the user can use the device's sinusoidal signal output function to provide signals for the verified instrument.

RTD Types Thermocouple Calibrators

The verification/calibration of some process recorders (especially mechanical recorders) usually involves the operation of the test. At this time, the device's sinusoidal signal output function can be used to signal the meter.

9.Data logging function

The logging function saves measurement and output data. PR231 series calibrator has powerful record management functions. Up to 32 device numbers can be created. Each device number has 16 logging pages. Each logging page contains four kinds of basic information, namely time, measured value, output value and custom value. Basic information. Users can perform device processing, record deletion, etc. according to their needs.

  • PR231 series model selection table

Item PR231A-1 PR231A-2 PR231B-1 PR231B-2
Enhancement model
Basic model
0.01 grade
0.02 grade

  • Basic Parameters

Weight 990g charging source 100~240V AC,50~60Hz
Dimension 225mm*130mm*53mm Working temperature -10℃~50℃
Cell type 7.4V 4400mAh, Rechargeable lithium battery Working time ≥20 hours(24V power off)
Preheating time 10 minutes after preheating Humidity 0~80%,Non condensing
Charging time 5 hours Calibration period 2 years

  • Performance Index

1. Basic parameters of measurement:

Function Range Measurement range Resolution 0.01 accuracy 0.02 accuracy Remarks
Voltage 100mV -5mV~120mV 0.1uV 0.005%RD+5uV

0.015%RD+

5uV

Input impedance

≥80mΩ

1V -50mV~1.2V 1uV

0.005%RD+

0.005%FS

0.015%RD+

0.005%FS

10V -0.5V~12V 10uV

Input impedance

≥1mΩ

50V -0.5V~50V 0.1mV
Current 50mA -5mA~50 mA 0.1uA 0.005%RD+0.005%FS

0.015%RD+

0.005%FS

Internal resistance =10Ω
Ohm 50Ω 0Ω~50Ω 0.1mΩ 0.005%RD+5mΩ

0.015%RD+

5mΩ

Output 1mA current
500Ω 0Ω~500Ω 1mΩ 0.005%RD+0.005%FS

0.015%RD+

0.005%FS

5kΩ 0kΩ~5kΩ 10mΩ Output 0.1mA current
Thermal couple S,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-26 0.1℃ / According to ITS-90 scale
Cold end compensation Internal -10℃~60℃ 0.01℃ 0.5℃ 0.5℃
External 0.1℃ 0.1℃

Thermal

resistance

Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt1000 0.01℃ /
Standard temperature S,R,B,T,SPt25,SPt100 0.01℃ / Need to enter the correction value
ρ-value 50S 0.001%~99.999% 0.001% 0.005% 0.005% Input pulse width amplitude range:1V~50V
Frequency 10Hz 0.001Hz~12Hz 0.001Hz 0.01%FS 0.01%FS
1kHz

0.00001kHz~

1.2 kHz

0.01Hz
100kHz

0.01kHz~

120 kHz

10Hz 0.1%FS 0.1%FS
Temperature difference S,R,B,K,N,J,E,T 0.01℃ / Need to enter the correction value
SPt25,SPt100 0.001℃

2. Basic parameters of the output function:

Function Range

Measurement

range

Resolution 0.01 accuracy 0.02 accuracy Remarks
Voltage 100mV -20mV~120mV 1uV 0.005%RD+5uV 0.015%RD+5uV Maximum load current =2.5mA
1V -0.2mV~1.2V 10uV 0.005%RD+0.005%FS 0.015%RD+0.005%FS
10V -2V~12V 0.1mV
Current 30mA -5mA~30 mA 1uA 0.005%RD+0.005%FS 0.015%RD+0.005%FS Maximum load voltage =24V
Ohm 50Ω 0Ω~50Ω 0.1mΩ / According to ITS-90 scale
500Ω 0Ω~500Ω 1mΩ
5kΩ 0kΩ~5kΩ 10mΩ
Thermal couple S,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-26 0.1℃ /

Thermal

resistance

Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt1000 0.01℃ /

Frequency

/ Pulse

10Hz

0.001Hz~

12 Hz

0.001Hz 0.01%FS 0.01%FS Maximum load current =2.5mA
1kHz

0.00001kHz~

1.2 kHz

0.01Hz

100kHz 0.01kHz~120 kHz 10Hz 0.1%FS 0.1%FS
Precision temperature control S,R,B,K,N,J,E,T 0.01℃ /
Pt100
24V output

Maximum voltage error: 0.3V Ripple noise:35mVp-p(20MHz bandwidth)

Maximum load current:70mA Load regulation: 0.5%(10% -100% load change)

  • DETAILS INTRODUCE

RTD Types Thermocouple Calibrators

RTD Types Thermocouple Calibrators

1. Measuring function terminal area (withstand 100V DC voltage input error)

2. Output function terminal area(withstand 36V DC voltage input error)

3. Dust cover

4. Side band(length adjustable )

5. Holder

6. External Pt100 Reference point sensor interface

7. USB2.0 communication interface

8. Multi-function port (With RS232 communication, USB communication, isolated 24V voltage output, precision temperature control signal output, pressure calibration, and other functions)

9. Reset

10. Supply hub(Connect the external AC power adapter)

11. Equipment nameplate

12. Battery

13.Protective tube

14.Screen contrast adjusting knob

15.Battery port

a.Adjust length here

b.Unfold jacket toward this direction

c. Holder unfold direction

Send your message to this supplier
Send Now

RTD Types Thermocouple Calibrators

Ask Latest Price
Brand Name :
PANRAN
Model Number :
PR231B-1
Certification :
CE,ISO9001
Place of Origin :
Tai'an,China
MOQ :
1 pcs
Price :
negotiable
Contact Supplier
RTD Types Thermocouple Calibrators
RTD Types Thermocouple Calibrators

Changsha Panran Technology Co., Ltd.

Active Member
5 Years
hunan, changsha
Since 1992
Business Type :
Manufacturer
Total Annual :
3000000-5000000
Employee Number :
100~150
Certification Level :
Active Member
Contact Supplier
Submit Requirement