Industrial First Class Type S Standard Thermocouple

Industrial First Class Type S Standard Thermocouple

Part1 Overview

The first and second grade standard platinum-iridium 10-platinum thermocouples which have high accuracy good physical and chemical properties, good oxidation resistance at high temperatures, good stability and reproducibility of thermoelectromotive force. Therefore, it is used as a standard measuring instrument in (419.527~1084.62) °C , it is also used to temperature magnitude transmit and precision temperature measure in the temperature range.

Part2 Technical parameters

Parameter index First grade platinum-iridium 10-platinum thermocouples Second grade platinum-iridium 10-platinum thermocouples
Positive and negative The positive is a platinum-rhodium alloy (platinum 90% rhodium 10%), the negative is pure platinum
electrode Two electrodes diameter is 0.5-0.015mm length is no less than 1000mm

Requirements of the thermal electromotive force

Measure junction temperature is at Cu point(1084.62℃)Al point(660.323℃)

Zn point(419.527℃) and reference junction temperature is 0℃

E(tCu)=10.575±0.015mV

E(tAl)=5.860+0.37 [E(tCu)-10.575]±0.005mV

E(tZn)=3.447+0.18 [E(tCu)-10.575]±0.005mV

Stability of Thermo-electromotive force 3μV 5μV
Annual change Thermo-electromotive force at Cu point(1084.62℃) ≦5μV ≦10μV
Working Temperature Range 300~1100℃
Insulating sleeve

Double hole porcelain tube or corundum tube

Outer diameter(3~4)mm, hole diameter(0.8~1.0)mm, length(500~550)mm

Part3 Application Instructions

standard platinum-iridium 10-platinum thermocouples must be in accordance with the national delivery system table,National verification procedures must be implemented. First grade standard platinum-iridium 10-platinum thermocouples can be used to measure second grade,Ⅰ grade,Ⅱ grade platinum-iridium 10-platinum thermocouples and Ⅰ grade base metal thermocouples; Second grade platinum-iridium 10-platinum thermocouples can only used to measure Ⅱ grade base metal thermocouples

National verification code National verification name
JJG75-1995 standard platinum-iridium 10-platinum thermocouples calibration specification
JJG141-2013 Working precious metal thermocouples calibration specification
JJF1637-2017 base metal thermocouple calibration specification

Part4 Maintenance and preservation

1.The standard thermocouple calibration period is 1 year, and every year the standard thermocouple must be calibrated by metrology department.

2. The necessary supervisory calibration should be performed according to the usage.

3. The work environment of the standard thermocouple should be clean to avoid contamination of the standard thermocouple.

4. The standard thermocouple should be placed in a non-polluting condition and protected from mechanical stress.

Part5 Precautions when use

1. The insulation tube cannot be used at high temperature roasting. The original insulation tube is used after strict cleaning and high temperature roasting.

2. The insulation tube ignores positive and negative, which will cause the platinum pole to be contaminated and the thermoelectric potential value to decrease.

3. Randomly the standard thermocouple insulation tube with cheap wire will contaminate the standard thermocouple, and the protective metal tube must be used for the verification of the base metal thermocouple.

4. The standard thermocouple cannot be suddenly placed in the temperature-regulating furnace, nor be taken out from the temperature-regulating furnace. The sudden-heat and cold will affect the thermoelectric performance

5. Under normal circumstances, the verification furnace for the precious metal thermocouple and the base metal thermocouple should be strictly distinguished; if it is impossible, the clean ceramic tube or corundum tube(diameter about 15mm) should be inserted to the furnace tube for protecting precious metal Thermocouples and standard thermocouples from base metal thermocouple pollution.

Send your message to this supplier
Send Now

Industrial First Class Type S Standard Thermocouple

Ask Latest Price
Brand Name :
PANRAN
Model Number :
PR1231/ PR1232
Certification :
CE,ISO9001
Place of Origin :
Tai'an,China
MOQ :
1 pcs
Price :
negotiable
Contact Supplier
Industrial First Class Type S Standard Thermocouple
Industrial First Class Type S Standard Thermocouple

Changsha Panran Technology Co., Ltd.

Active Member
5 Years
hunan, changsha
Since 1992
Business Type :
Manufacturer
Total Annual :
3000000-5000000
Employee Number :
100~150
Certification Level :
Active Member
Contact Supplier
Submit Requirement